QUANTITATIVE-EVALUATION OF DIGITAL DENTAL RADIOGRAPH IMAGING-SYSTEMS

被引:39
作者
HILDEBOLT, CF
VANNIER, MW
PILGRAM, TK
SHROUT, MK
机构
[1] WASHINGTON UNIV, SCH DENT MED, DIAGNOST SERV, ST LOUIS, MO 63130 USA
[2] MED COLL GEORGIA, SCH DENT, AUGUSTA, GA 30912 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1990年 / 70卷 / 05期
关键词
D O I
10.1016/0030-4220(90)90419-S
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Two digital imaging systems, a video camera and analog-to-digital converter, and a charge-coupled device linear photodiode array slide scanner, were tested for their suitability in quantitative studies of periodontal disease. The information content in the original films was estimated, and digital systems were assessed according to these requirements. Radiometric and geometric performance criteria for the digital systems were estimated from measurements and observations. The scanner-based image acquisition (digitization) system had no detectable noise and had a modulation transfer function curve superior to that of the video-based system. The scanner-based system was equivalent to the video-based system in recording radiographic film densities and had more geometric distortion than the video-based system. The comparison demonstrated the superiority of the charge-coupled device linear array system for the quantification of periodontal disease extent and activity. © 1990 Mosby-Year Book, Inc.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 9 条
[1]   COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS IN PERIODONTAL RADIOGRAPHY - A METHODOLOGICAL STUDY [J].
BRAGGER, D ;
PASQUALI, L ;
RYLANDER, H ;
CARNES, D ;
KORNMAN, KS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (01) :27-37
[2]   A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS [J].
DROEGE, RT ;
MORIN, RL .
MEDICAL PHYSICS, 1982, 9 (05) :758-759
[3]   A PRACTICAL METHOD TO ROUTINELY MONITOR RESOLUTION IN DIGITAL IMAGES [J].
DROEGE, RT .
MEDICAL PHYSICS, 1983, 10 (03) :337-343
[4]  
HILDEBOLT C, IN PRESS J PERIODONT
[5]   AUTOMATED CLASSIFICATION OF PERIODONTAL-DISEASE USING BITEWING RADIOGRAPHS [J].
HILDEBOLT, CF ;
VANNIER, MW .
JOURNAL OF PERIODONTOLOGY, 1988, 59 (02) :87-94
[6]   ROENTGENOGRAPHIC AND DISSECTION MEASUREMENTS OF ALVEOLAR CREST HEIGHT [J].
REGAN, JE ;
MITCHELL, DF .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1963, 66 (03) :356-&
[7]   INVESTIGATION INTO ACCURACY OF MEASUREMENTS MADE ON RADIOGRAPHS OF ALVEOLAR CRESTS OF DRIED MANDIBLES [J].
STONER, JE .
JOURNAL OF PERIODONTOLOGY, 1972, 43 (11) :699-701
[8]   A COMPARATIVE STUDY OF RADIOGRAPHS AND POCKET MEASUREMENTS IN PERIODONTAL DISEASE EVALUATION [J].
SUOMI, JD ;
PLUMBO, J ;
BARBANO, JP .
JOURNAL OF PERIODONTOLOGY, 1968, 39 (06) :311-&
[9]  
[No title captured]