HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF S-ADENOSYLMETHIONINE AND S-ADENOSYLHOMOCYSTEINE IN RAT-LIVER

被引:3
作者
FLORIDI, A
FINI, C
PALMERINI, CA
MOZZI, R
PORCELLATI, G
机构
[1] Istituto di Chimica Biologica, Universita di Perugia, 06100, Perugia
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1979年 / 2卷 / 07期
关键词
D O I
10.1080/01483917908060120
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and precise high performance liquid chromatographic method for the simultaneous quantitation of S-adenosylmethio-nine (SAMe) and S—adenosylhomocysteine (SAH) in rat liver is de-scribed. Liver is extracted by homogenization in 1,5 M PCA. SAMe and SAH are purified from contaminating substances by chromatography on Dow ex 50 W x 2 and analyzed by HPLC on conventional styrene-ty-pe anion exchanger. Analytical chromatography, performed under isocratic elution conditions, is achieved in 18 min. SAH is determined as such while SAMe as adenine after hydrolysis at 60° C, un der alkaline conditions. The sensitivity of the analytical proce dure allows the determination of SAMe and SAH in less than 200 mg of liver sample. © 1979, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:1003 / 1015
页数:13
相关论文
共 8 条
[1]  
BALDESSARINI ROSS J., 1963, ANALYT BIOCHEM, V6, P289, DOI 10.1016/0003-2697(63)90139-8
[2]   NEW METHOD FOR ASSAY OF TISSUE S-ADENOSYLHOMOCYSTEINE AND S-ADENOSYLMETHIONINE - EFFECT OF PYRIDOXINE-DEFICIENCY ON METABOLISM OF S-ADENOSYLHOMOCYSTEINE, S-ADENOSYLMETHIONINE AND POLYAMINES IN RAT-LIVER [J].
ELORANTA, TO ;
KAJANDER, EO ;
RAINA, AM .
BIOCHEMICAL JOURNAL, 1976, 160 (02) :287-294
[3]   SIMULTANEOUS ANALYSIS OF BASES, NUCLEOSIDES AND NUCLEOSIDE MONOPHOSPHATES AND POLYPHOSPHATES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FLORIDI, A ;
PALMERINI, CA ;
FINI, C .
JOURNAL OF CHROMATOGRAPHY, 1977, 138 (01) :203-212
[4]   RAPID LIQUID-CHROMATOGRAPHIC DETERMINATION OF S-ADENOSYLMETHIONINE AND S-ADENOSYLHOMOCYSTEINE IN SUBGRAM AMOUNTS OF TISSUE [J].
HOFFMAN, J .
ANALYTICAL BIOCHEMISTRY, 1975, 68 (02) :522-530
[5]   CO-USE OF RETENTION TIME AND BANDWIDTH MEASUREMENTS IN EVALUATIONS OF NUCLEOTIDE POOLS BY ION-EXCHANGE CHROMATOGRAPHY [J].
KHYM, JX ;
BYNUM, JW ;
VOLKIN, E .
ANALYTICAL BIOCHEMISTRY, 1977, 77 (02) :446-463
[6]  
PARKS LW, 1958, J BIOL CHEM, V230, P295
[7]   QUANTITATIVE ANALYSIS OF S-ADENOSYLMETHIONINE AND S-ADENOSYLHOMOCYSTEINE IN ANIMAL TISSUES [J].
SALVATOR.F ;
UTILI, R ;
ZAPPIA, V ;
SHAPIRO, SK .
ANALYTICAL BIOCHEMISTRY, 1971, 41 (01) :16-+
[8]   METHODS FOR ANALYSIS AND PREPARATION OF ADENOSYLMETHIONINE AND ADENOSYLHOMOCYSTEINE [J].
SHAPIRO, SK ;
EHNINGER, DJ .
ANALYTICAL BIOCHEMISTRY, 1966, 15 (02) :323-+