USE OF THE TERUMO SP CATHETER SYSTEM FOR CROSSING THE PULMONARY VALVE IN INFANTS WITH CRITICAL PULMONARY VALVE STENOSIS

被引:6
作者
ZELLERS, TM [1 ]
MOAKE, L [1 ]
WRIGHT, J [1 ]
机构
[1] CHILDRENS MED CTR,RYBUM HEART INST,DALLAS,TX 75235
关键词
D O I
10.1016/S0002-9149(99)80306-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We successfully performed pulmonary balloon valvuloplasty in 4 neonates with critical pulmonary stenosis. We initially crossed these pulmonary valves with a Terumo SP co-axial catheter system, We describe the technique and the excellent results with this procedure.
引用
收藏
页码:1082 / &
相关论文
共 7 条
[1]   MANAGEMENT OF NEONATAL CRITICAL PULMONIC STENOSIS IN THE BALLOON VALVOTOMY ERA [J].
CASPI, J ;
COLES, JG ;
BENSON, LN ;
FREEDOM, RM ;
BURROWS, PE ;
SMALLHORN, JF ;
TRUSLER, GA ;
WILLIAMS, WG .
ANNALS OF THORACIC SURGERY, 1990, 49 (02) :273-278
[2]  
LADUSANS EJ, 1990, BRIT HEART J, V63, P362
[3]   TRANSDUCTAL GUIDEWIRE RAIL FOR BALLOON VALVULOPLASTY IN NEONATES WITH ISOLATED CRITICAL PULMONARY VALVE STENOSIS OR ATRESIA [J].
LATSON, L ;
CHEATHAM, J ;
FROEMMING, S ;
KUGLER, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (09) :713-714
[4]   LONG-TERM RESULTS AFTER BALLOON PULMONARY VALVULOPLASTY [J].
MCCRINDLE, BW ;
KAN, JS .
CIRCULATION, 1991, 83 (06) :1915-1922
[5]   BALLOON VALVULOPLASTY OF PULMONARY STENOSIS IN INFANTS AND CHILDREN - CO-OPERATIVE STUDY OF THE GERMAN-SOCIETY OF PEDIATRIC CARDIOLOGY [J].
SCHMALTZ, AA ;
BEIN, G ;
GRAVINGHOFF, L ;
HAGEL, K ;
HENTRICH, F ;
HOFSTETTER, R ;
LINDINGER, A ;
KALLFELZ, HC ;
KRAMER, HH ;
MENNICKEN, U ;
MOCELLIN, R ;
PFEFFERKORN, JR ;
REDEL, D ;
RUPPRATH, G ;
SANDHAGE, K ;
SINGER, H ;
SEBENING, W ;
ULMER, H ;
VOGT, J ;
WESSEL, A .
EUROPEAN HEART JOURNAL, 1989, 10 (11) :967-971
[6]   BALLOON PULMONARY VALVULOPLASTY - RESULTS OF THE VALVULOPLASTY AND ANGIOPLASTY OF CONGENITAL-ANOMALIES REGISTRY [J].
STANGER, P ;
CASSIDY, SC ;
GIROD, DA ;
KAN, JS ;
LABABIDI, Z ;
SHAPIRO, SR .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (11) :775-783
[7]   CRITICAL PULMONARY VALVE STENOSIS IN THE NEONATE - A TECHNIQUE TO FACILITATE BALLOON DILATION [J].
WEBER, HS ;
CYRAN, SE ;
GLEASON, MM ;
WHITE, MG ;
BAYLEN, BG .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (04) :310-312