THE UTILITY OF DUPLEX ULTRASOUND SCANNING OF THE RENAL-ARTERIES FOR DIAGNOSING SIGNIFICANT RENAL-ARTERY STENOSIS

被引:274
作者
OLIN, JW [1 ]
PIEDMONTE, MR [1 ]
YOUNG, JR [1 ]
DEANNA, S [1 ]
GRUBB, M [1 ]
CHILDS, MB [1 ]
机构
[1] CLEVELAND CLIN FDN, DEPT BIOSTAT & EPIDEMIOL, CLEVELAND, OH 44195 USA
关键词
RENAL ARTERY; RENAL ARTERY OBSTRUCTION; ULTRASONOGRAPHY; DOPPLER; DUPLEX; ANGIOGRAPHY; HYPERTENSION; RENOVASCULAR;
D O I
10.7326/0003-4819-122-11-199506010-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the utility of duplex ultrasound scanning of the renal arteries in identifying patients with renal artery stenosis of 60% or more and in excluding patients with either normal renal arteries or renal artery stenosis of less than 60%. Design: A prospective, blinded study. Setting: Large tertiary referral center. Patients: 102 consecutive patients (44 men and 58 women with a mean age [+/-SD] of 63.3 +/- 13.4 years) who had both duplex ultrasound scanning of the renal arteries and renal arteriography. All patients who were studied had hypertension that was difficult to control, unexplained azotemia, or associated peripheral vascular disease (alone or in combination), giving them a high pretest likelihood of renovascular disease. Main Outcome Measurements: Peak systolic and end diastolic velocities, renal-aortic ratios, resistive index, and kidney sizes. Results: Sixty-two of 63 arteries with stenosis of less than 60% using arteriography were correctly identified by duplex ultrasound scanning. Thirty-one of 32 arteries with 60% to 79% stenosis using arteriography were correctly identified as having 60% to 99% stenosis on duplex ultrasound, whereas 67 of 69 arteries with 80% to 99% stenosis on arteriography were correctly identified as having 60% to 99% stenosis on ultrasound. Twenty-two of 23 arteries with total occlusion on arteriography were correctly identified by duplex ultrasound. The overall sensitivity of duplex ultrasound compared with arteriography was 0.98, the specificity was 0.98, the positive predictive value was 0.99, and the negative predictive value was 0.97. Conclusion: Duplex ultrasound scanning of the renal arteries is an ideal screening test because it is noninvasive and can predict the presence or absence of renal artery stenosis with a high degree of accuracy.
引用
收藏
页码:833 / 838
页数:6
相关论文
共 22 条
  • [1] Olin J.W., Melia M., Young J.R., Graor R.A., Risius B., Prevalence of atherosclerotic renal artery stenosis in patients in patients with atherosclerosis elsewhere, Am J Med, 88, (1990)
  • [2] Rimmer J.M., Gennari F.J., Atherosclerotic renal vascular disease and progressive renal failure, Ann Intern Med, 118, pp. 712-719, (1993)
  • [3] Mann S.J., Pickering T.G., Detection of renal vascular hypertension. State of the art: 1992, Ann Intern Med, 117, pp. 845-853, (1992)
  • [4] Davidson R.A., Wilcox C.S., Newer tests for the diagnosis of renal vascular disease, JAMA, 268, pp. 3353-3358, (1992)
  • [5] Olin J.W., Novick A.C., Renovascular disease, Textbook of Peripheral Vascular Diseases, pp. 267-284, (1991)
  • [6] Debatin J.F., Spritzer C.E., Grist T.M., Beam M.C., Svetkey L.P., Newman G.E., Et al., Imaging of the renal arteries: Value of MR angiography, AJR Am J Roentgenol, 157, pp. 981-990, (1991)
  • [7] Lewin J.S., Time-of-flight magnetic resonance angiography of the aorta and renal arteries, Invest Radiol, 27, 2 SUPPL., (1992)
  • [8] Rubin G.D., Walker P.J., Dake M.D., Napel S., Jeffrey R.B., McDonnell C.H., Et al., Three-dimensional spiral computed tomographic angiography: An alternative imaging modality for the abdominal aorta and its branches, J Vasc Surg, 18, pp. 656-664, (1993)
  • [9] Burns P.N., The physical principles of Doppler and spectral analysis, JCU J Clin Ultrasound, 15, pp. 567-590, (1987)
  • [10] Olin J.W., Role of duplex ultrasonography in screening for significant renal artery disease, Urol Clin North Am, 21, pp. 215-226, (1994)