AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF PARAQUAT AT THE SUBNANOGRAM PER MILLILITER LEVEL

被引:23
作者
AGUDO, M [1 ]
RIOS, A [1 ]
VALCARCEL, M [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
FLOW SYSTEM; PARAQUAT; SOIL ADSORPTION; WATERS;
D O I
10.1016/0003-2670(93)85344-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through spectrophotometric sensor for the determination of paraquat at the nanogram per milillitre level based on integration of preconcentration, reaction and detection in the flow-cell is proposed. The determination range achieved depends on the sample volume used. Thus, 250 ml of sample provides detection and determination limits of 0.11 and 0.44 ng ml-1 paraquat, respectively. The relative standard deviation was +/-7.9% for 1.0 ng ml-1 paraquat. The potential interference of other pesticides was studied, and the method was used to analyse water samples and study the adsorption of paraquat in different types of soils.