THE LOCATION OF THE CERVICAL NERVE ROOTS ON THE POSTERIOR ASPECT OF THE CERVICAL-SPINE

被引:34
作者
XU, RM
EBRAHEIM, NA
NADAUD, MC
YEASTING, RA
STANESCU, S
机构
[1] MED COLL OHIO,DEPT ORTHOPAED SURG,TOLEDO,OH 43614
[2] MED COLL OHIO,DEPT ANAT,TOLEDO,OH 43699
关键词
Cervical nerve root; Cervical spine; Lateral mass screw; Posterior cervical plating;
D O I
10.1097/00007632-199511000-00001
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This study analyzed anatomic parameters between the midpoint of cervical vertebral lateral the mass as seen on the superficial, posterior aspect of the mass and cervical nerve roots. Posterior cervical dissection was performed, with the midpoint of the lateral masses kept intact and the nerve roots exposed. Objective, To quantitatively determine the location of the cervical nerve roots and the transverse foramina, indicating vertebral artery placement relative to the posterior aspect of the cervical spine. Summary of Background Data, Posterior plate-screw fixation of the cervical spine has been widely used to treat unstable fractures of the cervical spine. However, injury to the spinal nerve roots during the procedure remains an important concern. No previous anatomic study regarding the location of the cervical nerve roots relative to the posterior aspect of the cervical spine has been reported. Methods. Fifteen specimens were obtained for study of the cervical spine. Laminectomy and partial removal of the superior and inferior articular facets then were performed on C2-C3 through C7-T1 to expose the nerve roots and dura. Photographs, containing a reference scale, were taken simultaneously perpendicular to the sagittal and transverse planes of the specimen. Using enlarged versions of the photographs, independent measurements by several observers were taken from the superficial, posterior center of each lateral mass to the nerve root superiorly and inferiorly,and to the lateral limits of the dura. Vertebrae from an additional 20 spines were examined to determine the position of the transverse foramina relative to the lateral mass of the vertebrae. Results. The results showed that for C3-C7, the average distance from the superficial, posterior center of the lateral mass to the nerve root superiorly was 5.7 +/- 1.5 mm. Inferiorly, the average distance was 5.5 +/- 0.8 mm. The average distance from the lateral mass to the spinal cord dura was 9.2 +/- 1.4 mm, and the average medial angle of the nerve root was 76.3 degrees + 4.4 degrees. For cervical vertebrae C3-C5, the transverse foramina were situated medial to the posterior center of the lateral mass. At the C6 level, the transverse foramina were situated ,anterior to the posterior midpoint of the lateral mass. Conclusion. This study demonstrates that the posterior midpoint of the lateral mass is a safe point for initiating screw insertion.
引用
收藏
页码:2267 / 2271
页数:5
相关论文
共 9 条
[1]  
An H.S., Hordin R., Renner K., Anatomic considerations for plate-screw fixation of the cervical spine, Spine, 16, pp. 548-551, (1991)
[2]  
Anderson P.A., Henley M.B., Grady M.S., Montesano P.X., Winn H.R., Posterior cervical arthrodesis with AO reconstruction plates and bone graft, Spine, 16, pp. 72-79, (1991)
[3]  
Dominella G., Berlanda P., Bassi G., Posterior approach osteosynthesis of the lower cervical spine by the R. Roy- Camille technique, Ital J Orthop Traumatol, 8, pp. 235-244, (1982)
[4]  
Ebraheim N.A., An H.S., Jackson W.T., Brown J.A., Internal fixation of the unstable cervical spine using posterior Roy- Camille plates: Preliminary report, J Orthop Trauma, 3, pp. 23-28, (1989)
[5]  
Ebraheim N.A., Hoeflinger M.J., Salpietro B., Chung S., Jackson W.T., Anatomic considerations in posterior plating of the cervical spine, J Orthop Trauma, 5, pp. 196-199, (1991)
[6]  
Heller J.G., Carlson G.D., Abitbol J.-J., Garfin S.R., Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine, Spine, 16, pp. 552-556, (1991)
[7]  
Nazarian S.M., Louis R.P., Posterior Internal Fixation with Screw Plates in Traumatic Lesions of the Cervical Spine, 16, pp. 64-71, (1991)
[8]  
Roy-Camille R., Saillant G., Laville C., Benazat J.P., Treatment Spine, 17, pp. 442-446, (1992)
[9]  
Roy-Camille R., Saillant G., Mazel C., Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws, The Cervical Spine, pp. 390-403, (1989)