DETERMINING RATIO OF HORIZONTAL TO VERTICAL PERMEABILITY BY AQUIFER-TEST ANALYSIS

被引:49
作者
WEEKS, EP
机构
关键词
D O I
10.1029/WR005i001p00196
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ratio of horizontal to vertical permeability may be determined by analysis of drawdown data from piezometers or partially penetrating observation wells near a partially penetrating production well. The analyses are made by comparing measured drawdowns in the piezometers to those predicted if the production well fully penetrated the aquifer. The differences between the measured and predicted drawdowns are determined, and the distances from the pumped well at which these differences would occur in an isotropic aquifer are determined from an equation. The permeability ratio is computed as the square of the ratio of actual distances to computed distances. The ratio of horizontal to vertical permeability in glacial outwash in central Wisconsin was determined from 5 aquifer tests to range from about 2 to about 20. Copyright 1969 by the American Geophysical Union.
引用
收藏
页码:196 / &
相关论文
共 23 条
[1]  
BABBITT HE, 1948, 374 U ILL ENG EXPT S, P47
[2]  
Boulton N. S., 1963, ICE P, V26, P469
[3]  
BOULTON NS, 1954, INT ASSOC SCI HYDROL, V2, P427
[4]  
BUTLER SS, 1957, ENGINEERING HYDROLOG, P129
[5]  
CASAGRANDE A, 1937, NEW ENG WATER WORKS, P295
[6]  
CHOW VT, 1964, ADVANCES HYDROSCI ED, V1, P281
[7]  
CREAGER WP, 1945, ENGINEERING DAMS
[9]  
FERRIS JG, 1962, 1536E US GEOL SURV W, P69
[10]  
Hantush M.S., 1964, ADV HYDROSCI, VVolume 1, P281, DOI 10.1016/B978-1-4831-9932-0.50010-3