EFFECT OF HUMIDITY ON THE DESWELLING FUNCTION OF THE HUMAN CORNEA

被引:12
作者
BOURASSA, S
BENJAMIN, WJ
BOLTZ, RL
机构
[1] UNIV ALABAMA,SCH OPTOMETRY,BIRMINGHAM,AL 35294
[2] UNIV HOUSTON,COLL OPTOMETRY,HOUSTON,TX 77004
关键词
D O I
10.3109/02713689109001757
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The present study determined the effect of the full range of humidities on the deswelling function of the human cornea. The closed-eye deswelling function and the open-eye deswelling responses for five different levels of humidity (0%, 25%, 60%, 85%, and 100%) were assessed for 8 normal, young-adult subjects. Open-eye corneal deswelling for the 8 subjects was unaffected by relative humidities from 0 to 100%. Therefore, osmotically-driven corneal thinning effect of tear evaporation does not significantly contribute to the deswelling function of the human cornea. We conclude, contrary to recent reports, that the endothelial pump is the primary mechanism that maintains normal corneal thickness and provides recovery from stromal edema.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 20 条