INTEGRATION OF ABSOLUTE VENTRICULAR-FIBRILLATION VOLTAGE CORRELATES WITH SUCCESSFUL DEFIBRILLATION

被引:31
作者
KUELZ, KW [1 ]
HSIA, PW [1 ]
WISE, RM [1 ]
MAHMUD, R [1 ]
DAMIANO, RJ [1 ]
机构
[1] E CAROLINA UNIV,GREENVILLE,NC 27858
关键词
D O I
10.1109/10.310093
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous work has suggested that at higher absolute ventricular fibrillatian voltages (AVFV), the heart is more amenable to defibrillation. This study investigated in a canine model whether voltage integration of the AVFV is associated with the defibrillation success rate. The moving-average filter was used to process the ventricular fibrillation (VF) waveform recorded from Lead LI of the electrocardiogram (ECG). In seven animals, defibrillation trials were analyzed using a de shock (DCS) suc- cessful approximately 50% of the time when delivered randomly. For each of a total of 84 DCS (40% successes, 60% failures), the fibrillation waveform just prior to DCS was analyzed. The integration of the AVFV waveform was performed over various sample sizes including 1, 4, 8, 16, 64, and 128 ms, as well as the time equal to the mean VF cycle length. The results suggest that de shocks delivered at instants of higher values of integrated AVFV over the various window sizes are associated with successful defibrillation. Window sizes less than 16 ms appeared to offer the best discrimination, The integration of AVFV over the entire VF cycle length was significantly higher for successful rather than unsuccessful DCS. This interesting observation is consistent with the clinical observation that ''coarse'' VF (high AVFV) is easier to defibrillate than ''fine'' VF (low AVFV). The use of voltage integration of AVFV may have potential implications in the improvement of defibrillation success in implantable devices.
引用
收藏
页码:782 / 791
页数:10
相关论文
共 63 条
[1]  
ALLEN JD, 1979, J PHYSIOL-LONDON, V293, pP23
[2]   VENTRICULAR DEFIBRILLATION THRESHOLDS WITH CAPACITOR DISCHARGE [J].
ARMAYOR, MR ;
SAVINO, G ;
VALENTINUZZI, ME ;
CLAVIN, OE ;
MONZON, JE ;
ARREDONDO, MT .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (04) :435-442
[3]  
ARREDONDO MT, 1982, MED PROG TECHNOL, V8, P175
[4]   A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[5]  
BLACK JN, 1987, J AM COLL CARDIOL, V9, pA142
[6]  
BOURLAND JD, 1986, MED INSTRUM, V20, P138
[7]   COMPARISON OF MONOPHASIC WITH SINGLE AND DUAL CAPACITOR BIPHASIC WAVEFORMS FOR NONTHORACOTOMY CANINE INTERNAL DEFIBRILLATION [J].
CHAPMAN, PD ;
VETTER, JW ;
SOUZA, JJ ;
WETHERBEE, JN ;
TROUP, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (01) :242-245
[8]   MECHANISM OF CARDIAC DEFIBRILLATION - A DIFFERENT POINT-OF-VIEW [J].
CHEN, PS ;
WOLF, PD ;
IDEKER, RE .
CIRCULATION, 1991, 84 (02) :913-919
[9]   COMPARISON OF THE DEFIBRILLATION THRESHOLD AND THE UPPER LIMIT OF VENTRICULAR VULNERABILITY [J].
CHEN, PS ;
SHIBATA, N ;
DIXON, EG ;
MARTIN, RO ;
IDEKER, RE .
CIRCULATION, 1986, 73 (05) :1022-1028
[10]   MYOCARDIAL NECROSIS FROM DIRECT-CURRENT COUNTERSHOCK - EFFECT OF PADDLE ELECTRODE SIZE AND TIME INTERVAL BETWEEN DISCHARGES [J].
DAHL, CF ;
EWY, GA ;
WARNER, ED ;
THOMAS, ED .
CIRCULATION, 1974, 50 (05) :956-961