ACCURACY OF THE EUROPEAN SOLAR WATER-HEATER TEST PROCEDURE .2. PREDICTION OF LONG-TERM PERFORMANCE

被引:9
作者
BOURGES, B
RABL, A
CARVALHO, MJ
COLLARESPEREIRA, M
机构
[1] ECOLE MINES,CTR ENERGET,F-75272 PARIS 06,FRANCE
[2] LAB NACL ENGN & TECHNOL IND,DEPT ENERGIAS RENOVAVEIS,P-1699 LISBODA,PORTUGAL
关键词
D O I
10.1016/0038-092X(91)90059-6
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper continues the evaluation of the European test procedure for solar water heaters, by considering what consequences the errors of the parameters (derived in Part 1, the companion paper) will have for the prediction of the long-term performance. A simple criterion is derived for the required length of the test period, as a function of climatic variables and desired accuracy of the long-term performance prediction. Typically a duration of 10 to 50 days will suffice. Since the actual conditions during a test cannot be foreseen, it will be more efficient to calculate the error of the long-term performance prediction on line at the end of each test day and terminate the series whenever acceptable accuracy is reached.