ELECTRON BOLUS DESIGN FOR RADIOTHERAPY TREATMENT PLANNING - BOLUS DESIGN ALGORITHMS

被引:66
作者
LOW, DA [1 ]
STARKSCHALL, G [1 ]
BUJNOWSKI, SW [1 ]
WANG, LL [1 ]
HOGSTROM, KR [1 ]
机构
[1] UNIV TEXAS,MD ANDERSON CANC CTR,HOUSTON,TX 77030
关键词
ELECTRON BEAM RADIOTHERAPY; ELECTRON BOLUS DESIGN; ELECTRON CONFORMAL THERAPY;
D O I
10.1118/1.596885
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer algorithms to design bolus for electron beam radiotherapy treatment planning were investigated. Because of the significant electron multiple scatter, there is no unique solution to the problem of bolus design. However, using a sequence of operators, a bolus can be designed that attempts to meet three important criteria: adequate dose delivery to the target volume, avoidance of critical structures, and dose homogeneity within the target volume. Initial calculation of bolus shape was based upon creation operators forcing either the physical or the effective depths of the distal surface of the target volume to a specified value. Modification operators were then applied to the bolus to alter the shape to better meet the design criteria. Because the operators each address a single dosimetric issue, they can often adversely affect some other attribute of the dose distribution. In addition, an extension operator is used to design the bolus thickness outside the target volume. Application of these operators is therefore carried out in certain sequences and each may be used more than once in the design of a particular bolus. The effects of these operators on both the bolus and the resulting dose distribution are investigated for test geometries and patient geometries in the nose, parotid, and paraspinal region.
引用
收藏
页码:115 / 124
页数:10
相关论文
共 28 条
[1]   COMPENSATION TECHNIQUES IN NIRS PROTON-BEAM RADIOTHERAPY [J].
AKANUMA, A ;
MAJIMA, H ;
FURUKAWA, S ;
OKAMOTO, R ;
NAKAMURA, YK ;
TSUNEMOTO, H ;
MORITA, S ;
ARAI, T ;
KURISU, A ;
HIRAOKA, T ;
KAWACHI, K ;
KANAI, T .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (09) :1629-1635
[2]  
ANDREW JW, 1987, USE COMPUTERS RAD TH, P315
[3]   USE OF VARIABLE THICKNESS BOLUS TO CONTROL ELECTRON-BEAM PENETRATION IN CHEST WALL IRRADIATION [J].
ARCHAMBEAU, JO ;
FORELL, B ;
DORIA, R ;
FINDLEY, DO ;
JURISCH, R ;
JACKSON, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (06) :835-842
[4]  
BEACH JL, 1981, INT J RADIAT ONCOL, V7, P1607
[5]   TREATMENT PLANNING FOR HEAVY-ION RADIOTHERAPY [J].
CHEN, GTY ;
SINGH, RP ;
CASTRO, JR ;
LYMAN, JT ;
QUIVEY, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (10) :1809-1819
[6]   THE PROBLEM OF OBLIQUELY INCIDENT BEAMS IN ELECTRON-BEAM TREATMENT PLANNING [J].
EKSTRAND, KE ;
DIXON, RL .
MEDICAL PHYSICS, 1982, 9 (02) :276-278
[7]   PARTIAL BOLUSSING TO IMPROVE THE DEPTH DOSES IN THE SURFACE REGION OF LOW-ENERGY ELECTRON-BEAMS [J].
GALBRAITH, DM ;
RAWLINSON, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (02) :313-317
[8]   COMPENSATION FOR INHOMOGENEITIES IN CHARGED-PARTICLE RADIOTHERAPY USING COMPUTED TOMOGRAPHY [J].
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (5-6) :499-508
[9]   WATER BAG BOLUS IN EXTERNAL AIR CAVITIES TO PRODUCE DOSE HOMOGENEITY [J].
HASELOW, RE ;
KHAN, FM ;
SHARMA, SC ;
WILLIAMSON, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (01) :137-139
[10]  
HOGSTROM K R, 1979, Medical Physics (Woodbury), V6, P26, DOI 10.1118/1.594548