A procedure is described for detection and quantitation of ethylene oxide and two major reaction products. Detection of ethylene oxide residuals extracted from alcohol pads (cellulose) and plastic material is illustrated. Quantitation of the three compounds can be obtained with a single gas chromatographic (GC) analysis. A DB-Wax-30N, 0.25 mm i.d. column is used with 1:50 split injections with dimethyl-formamide as the solvent and 1:100 split injections with water as the solvent. A DB-Wax-30W, 0.32 mm i.d. column is used for on-column injections and 1:100 split water injections. Linearity of the three compounds is demonstrated.; A procedure is described for detection and quantitation of ethylene oxide and two major reaction products. Detection of ethylene oxide residuals extracted from alcohol pads (cellulose) and plastic material is illustrated. Quantitation of the three compounds can be obtained with a single gas chromatographic (GC) analysis. A DB-Wax-30N, 0.25 mm i.d. column is used with 1:50 split injections with dimethylformamide as the solvent and 1:100 split injections with water as the solvent. A DB-Wax-30W, 0.32 mm i.d. column is used for on-column injections and 1:100 split water injections. Linearity of the three compounds is demonstrated.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 26 条
[1]  
[Anonymous], 1986, RECOMMENDED PRACTICE
[2]  
[Anonymous], 1985, RECOMMENDED PRACTICE
[3]  
BALL NA, 1984, J PHARM SCI, V73, P1305, DOI 10.1002/jps.2600730932
[4]  
Bicchi C, 1980, Farmaco Prat, V35, P632
[5]  
BROWN DJ, 1970, J ASSOC OFF ANA CHEM, V53, P263
[6]  
CRAM DJ, ORGANIC CHEM, P248
[7]   GAS-CHROMATOGRAPHIC DETERMINATION OF RESIDUAL ETHYLENE-OXIDE IN GAS-STERILIZED, MEDICAL-GRADE PLASTICS [J].
DERUDDER, D ;
REMON, JP ;
DEGRAEVE, E ;
VANSEVEREN, R ;
BRAECKMAN, P .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (10) :587-589
[8]   A HEADSPACE GAS-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF TRACES OF ETHYLENE-OXIDE IN STERILIZED MEDICAL DEVICES [J].
GRAMICCIONI, L ;
MILANA, MR ;
DIMARZIO, S .
MICROCHEMICAL JOURNAL, 1985, 32 (01) :89-93
[9]   SIMPLE GLC DETERMINATION OF ETHYLENE-OXIDE AND ITS REACTION-PRODUCTS IN DRUGS AND FORMULATIONS [J].
HARTMAN, PA ;
BOWMAN, PB .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (06) :789-792
[10]   STATISTICAL EVALUATION OF METHODS USING HEADSPACE GAS-CHROMATOGRAPHY FOR THE DETERMINATION OF ETHYLENE-OXIDE [J].
KAYE, MM ;
NEVELL, TG .
ANALYST, 1985, 110 (09) :1067-1071