MAGNETOOPTIC MAGNETIC-FIELD SENSOR WITH 1.4PT/ROOT(HZ) MINIMUM DETECTABLE FIELD AT 1 KHZ

被引:16
作者
DEETER, MN [1 ]
DAY, GW [1 ]
BEAHN, TJ [1 ]
MANHEIMER, M [1 ]
机构
[1] US DEPT DEF,PHYS SCI LAB,COLL PK,MD 20740
关键词
MAGNETOOPTICAL DEVICES; MEASUREMENT;
D O I
10.1049/el:19930661
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Letter demonstrates that the sensitivity of magneto-optic magnetic field sensors employing iron garnets can be increased by approximately two orders of magnitude by applying flux concentration. A minimum detectable field of 1.4 pT/square-root (Hz) was measured when a cylindrical gallium-substituted yttrium iron garnet crystal was combined with two conically tapered nickel-zinc ferrite cylinders.
引用
收藏
页码:993 / 994
页数:2
相关论文
共 3 条
[1]   FAST, SENSITIVE MAGNETIC-FIELD SENSORS BASED ON THE FARADAY-EFFECT IN YIG [J].
DEETER, MN ;
ROSE, AH ;
DAY, GW .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1990, 8 (12) :1838-1842
[2]   SENSITIVITY LIMITS TO FERRIMAGNETIC FARADAY-EFFECT MAGNETIC-FIELD SENSORS [J].
DEETER, MN ;
ROSE, AH ;
DAY, GW ;
SAMUELSON, S .
JOURNAL OF APPLIED PHYSICS, 1991, 70 (10) :6407-6409
[3]  
DEETER MN, 1990, P SOC PHOTO-OPT INS, V1367, P243