EFFECT OF LUNG-VOLUME ON LUNG RESISTANCE AND ELASTANCE IN AWAKE SUBJECTS MEASURED DURING SINUSOIDAL FORCING

被引:27
作者
BARNAS, GM
SPRUNG, J
CRAFT, TM
WILLIAMS, JE
RYDER, IG
YUN, JA
MACKENZIE, CF
机构
[1] UNIV MARYLAND,SCH MED,DEPT ANESTHESIOL,BALTIMORE,MD 21201
[2] UNIV MARYLAND,SCH MED,DEPT PHYSIOL,BALTIMORE,MD 21201
关键词
AIRWAY PRESSURE; COMPLIANCE; MECHANICS OF BREATHING;
D O I
10.1097/00000542-199306000-00010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Although lung volume may be changed by certain procedures during anesthesia and mechanical ventilation, dependence of the dynamic mechanical properties of the lungs on lung volume are not clear. Based on studies in dogs, the authors hypothesized that changes in lung mechanics caused by anesthesia in healthy humans could be accounted for by immediate changes in lung volume and that lung resistance will not be decreased by positive end-expiratory airway pressure if tidal volume and respiratory frequency are in the normal ranges. Methods. Lung resistance and dynamic lung elastance were measured in six healthy, relaxed, seated subjects during sinusoidal volume oscillations at the mouth (5 mL/kg; 0.4 Hz) delivered at mean airway pressure from -9 to +25 cmH2O. Changes in lung volume from functional residual capacity were measured with inductance plethysmographic belts. Results. Decreases in mean mean airway pressure that caused decreases in lung volume from functional residual capacity comparable to those typically observed during anesthesia were associated with significant increases in both dynamic lung elastance and lung resistance. Increases in mean mean airway pressure that caused increases in lung volume from functional residual capacity did not increase lung resistance and increased dynamic lung elastance only above about 15 cmH2O. Conclusions. Increases in dynamic lung elastance and lung resistance with anesthesia can be explained by the accompanying, acute decreases in lung volume, although other factors may be involved. Increasing lung volume by increasing mean airway pressure with positive end-expiratory pressure will decrease lung resistance only if the original lung volume is low compared to awake, seated functional residual capacity.
引用
收藏
页码:1082 / 1090
页数:9
相关论文
共 38 条
  • [1] AGOSTONI E, 1964, HANDBOOK PHYSIOLOG 3, V1, P387
  • [2] LUNG, CHEST-WALL, AND TOTAL RESPIRATORY SYSTEM RESISTANCES AND ELASTANCES IN THE NORMAL RANGE OF BREATHING
    BARNAS, GM
    CAMPBELL, DN
    MACKENZIE, CF
    MENDHAM, JE
    FAHY, BG
    RUNCIE, CJ
    MENDHAM, GE
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (01): : 110 - 113
  • [3] BARNAS GM, IN PRESS J APPL PHYS
  • [4] BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
  • [5] LUNG-MECHANICS IN SITTING AND HORIZONTAL BODY POSITIONS
    BEHRAKIS, PK
    BAYDUR, A
    JAEGER, MJ
    MILICEMILI, J
    [J]. CHEST, 1983, 83 (04) : 643 - 646
  • [6] RELATIONSHIP BETWEEN AIRWAY RESISTANCE, AIRWAY CONDUCTANCE AND LUNG VOLUME IN SUBJECTS OF DIFFERENT AGE AND BODY SIZE
    BRISCOE, WA
    DUBOIS, AB
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1958, 37 (09) : 1279 - 1285
  • [7] PARTITIONING OF PULMONARY RESISTANCE IN DOGS - EFFECT OF TIDAL VOLUME AND FREQUENCY
    BRUSASCO, V
    WARNER, DO
    BECK, KC
    RODARTE, JR
    REHDER, K
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (03) : 1190 - 1196
  • [8] SOME EFFECTS OF RESTRICTION OF CHEST CAGE EXPANSION ON PULMONARY FUNCTION IN MAN - AN EXPERIMENTAL STUDY
    CARO, CG
    BUTLER, J
    DUBOIS, AB
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1960, 39 (04) : 573 - 583
  • [9] ROLE OF INERTIA IN MEASUREMENT OF DYNAMIC COMPLIANCE
    DOSMAN, J
    BODE, F
    URBANETTI, J
    ANTIC, R
    MARTIN, R
    MACKLEM, PT
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (01) : 64 - 69
  • [10] COMPUTER MEASUREMENT OF DYNAMIC COMPLIANCE - TECHNIQUE AND REPRODUCIBILITY IN MAN
    DOUGLAS, NJ
    WRAITH, PK
    BRASH, HM
    MILLAR, J
    SUDLOW, MF
    FLENLEY, DC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1980, 48 (05) : 903 - 910