FLOW CYTOMETRIC MEASUREMENT OF IMMUNOGLOBULIN-E TO NATURAL LATEX PROTEINS

被引:12
作者
KWITTKEN, PL
PAWLOWSKI, NA
SWEINBERG, SK
DOUGLAS, SD
CAMPBELL, DE
机构
[1] CHILDRENS HOSP, DIV ALLERGY IMMUNOL & INFECT DIS, PHILADELPHIA, PA 19104 USA
[2] UNIV PENN, CHILDRENS HOSP PHILADELPHIA, SCH MED, DEPT PEDIAT, PHILADELPHIA, PA 19104 USA
[3] CHILDRENS HOSP, CLIN IMMUNOL LAB, PHILADELPHIA, PA 19104 USA
关键词
D O I
10.1128/CDLI.1.2.197-201.1994
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Immediate hypersensitivity to natural Latex (NL) occurs in sensitized individuals after repeated exposure to products or devices containing NL components. Since allergic reactions to NL proteins are quite frequent acid may be quite serious, diagnostic assays are needed to identify individuals at risk. A number of latex proteins have been considered the major antigens, but they have been incompletely characterized. There is no standard material available for skin testing, In vitro diagnostic tests, such as the radioallergosorbent test (RAST), are lime consuming and their sensitivity and specificity remain to be proven. We have developed a rapid, microsphere-based, fluorescence-activated flow cytometry assay for the measurement of NL protein-specific human immunoglobulin E and have compared it with both the enzyme-linked immunosorbent assay and radioallergosorbent test methods. By using the total purified NL protein fraction isolated from raw ammoniated NL sap as the antigen, the how cytometry assay was both sensitive and specific for the detection of NL protein-specific human immunoglobulin E in the sera of sensitized pediatric patients.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 25 条
[1]   DETECTION OF IGG4 AND IGE ANTIBODIES TO RUBBER PROTEINS BY IMMUNOBLOTTING IN LATEX ALLERGY [J].
ALENIUS, H ;
REUNALA, T ;
TURJANMAA, K ;
PALOSUO, T .
ALLERGY PROCEEDINGS, 1992, 13 (02) :75-77
[2]   INDIRECT ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR MEASUREMENT OF HUMAN IMMUNOGLOBULIN-E AND IMMUNOGLOBULIN-G TO PURIFIED COWS MILK-PROTEINS - APPLICATION IN DIAGNOSIS OF COWS MILK ALLERGY [J].
CAMPBELL, DE ;
NGAMPHAIBOON, J ;
CLARK, MM ;
HARRIS, MC ;
KOLSKI, GB ;
DOUGLAS, SD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (11) :2114-2119
[3]   CONTACT URTICARIA AND RHINITIS FROM LATEX SURGICAL GLOVES [J].
CARRILLO, T ;
CUEVAS, M ;
MUNOZ, T ;
HINOJOSA, M ;
MONEO, I .
CONTACT DERMATITIS, 1986, 15 (02) :69-72
[4]   DERMATITIS AND URTICARIA FROM RUBBER AND PLASTIC GLOVES [J].
ESTLANDER, T ;
JOLANKI, R ;
KANERVA, L .
CONTACT DERMATITIS, 1986, 14 (01) :20-25
[5]   INTRAOPERATIVE ANAPHYLAXIS - AN ASSOCIATION WITH LATEX SENSITIVITY [J].
GOLD, M ;
SWARTZ, JS ;
BRAUDE, BM ;
DOLOVICH, J ;
SHANDLING, B ;
GILMOUR, RF .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1991, 87 (03) :662-666
[6]   LATEX HYPERSENSITIVITY REACTIONS DESPITE PROPHYLAXIS [J].
KWITTKEN, PL ;
BECKER, J ;
OYEFARA, B ;
DANZIGER, R ;
PAWLOWSKI, NA ;
SWEINBERG, S .
ALLERGY PROCEEDINGS, 1992, 13 (03) :123-127
[7]   A FLUORESCENCE IMMUNOASSAY FOR SOLUBLE-ANTIGENS EMPLOYING FLOW CYTOMETRIC DETECTION [J].
LISI, PJ ;
HUANG, CW ;
HOFFMAN, RA ;
TEIPEL, JW .
CLINICA CHIMICA ACTA, 1982, 120 (02) :171-179
[8]  
LOWRY OH, 1951, J BIOL CHEM, V193, P265
[9]   FLOW CYTOMETRIC DETECTION AND QUANTITATION OF IMMUNE-COMPLEXES USING HUMAN C1Q-COATED MICROSPHERES [J].
MCHUGH, TM ;
STITES, DP ;
CASAVANT, CH ;
FULWYLER, MJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 95 (01) :57-61
[10]   SIMULTANEOUS DETECTION OF ANTIBODIES TO CYTOMEGALO-VIRUS AND HERPES-SIMPLEX VIRUS BY USING FLOW-CYTOMETRY AND A MICROSPHERE-BASED FLUORESCENCE IMMUNOASSAY [J].
MCHUGH, TM ;
MINER, RC ;
LOGAN, LH ;
STITES, DP .
JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (10) :1957-1961