COMPARATIVE DETERMINATION OF PLASMA CHOLESTEROL AND TRIACYLGLYCEROL LEVELS BY AUTOMATED GAS-LIQUID-CHROMATOGRAPHIC AND AUTOANALYZER METHODS

被引:67
作者
KUKSIS, A [1 ]
MYHER, JJ [1 ]
GEHER, K [1 ]
HOFFMAN, AGD [1 ]
BRECKENRIDGE, WC [1 ]
JONES, GJL [1 ]
LITTLE, JA [1 ]
机构
[1] UNIV TORONTO,TORONTO MCMASTER LIPID RES CLIN PROJECT,TORONTO,ONTARIO,CANADA
来源
JOURNAL OF CHROMATOGRAPHY | 1978年 / 146卷 / 03期
基金
英国医学研究理事会;
关键词
D O I
10.1016/S0378-4347(00)81198-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasma samples obtained during a prevalence study of hyperlipemia in a free living urban population were analyzed for total cholesterol and triacylglycerol content by automated high-temperature gas-liquid chromatographic (GLC) and automated colorimetric (Auto-Analyzer, AA11) methods. The analyses were done over a three-year period. The methods gave excellent overall correlation for both total cholesterol (r = 0.9811) and total triacylglycerols (r = 0.9739). Detailed comparisons of the results obtained by the two methods with natural samples over the entire concentration range, indicated that the GLC method gave cholesterol values 5-10 mg% lower and triacylglycerol values 10-20 mg% lower than the corresponding AA11 determinations. The differences between the two methods are attributed to an overestimation of the cholesterol and triacylglycerol levels by the AA11 method due to presence of variable amounts of interfering chromogens in the plasma extracts. The between-method relative error ranged from 3 to 5% for cholesterol and from 5 to 10% for triacylglycerols. The within-day standard deviation of GLC averaged 2.3 mg% for cholesterol and 3.5 mg% for triacylglycerols. The between-day standard deviation of the GLC method averaged about 6 mg% for both cholesterol and triacylglycerols. The within-day, within GLC, relative error averaged 1.12% for cholesterol and 2.66% for tri-acylglycerols. The apparent high precision and high accuracy of the GLC method recommend it as an alternative to the indirect methods of plasma cholesterol and triacylglycerol analysis, especially where a smaller throughput of samples is not a limitation and where both total amount and composition of the lipids is of interest. © 1978.
引用
收藏
页码:393 / 412
页数:20
相关论文
共 19 条
[1]   DETERMINATION OF SERUM TRIGLYCERIDES BY MASS FRAGMENTOGRAPHY [J].
BJORKHEM, I ;
BLOMSTRAND, R ;
SVENSSON, L .
CLINICA CHIMICA ACTA, 1976, 71 (02) :191-198
[2]   SERUM-CHOLESTEROL DETERMINATION BY MASS FRAGMENTOGRAPHY [J].
BJORKHEM, I ;
BLOMSTRAND, R ;
SVENSSON, L .
CLINICA CHIMICA ACTA, 1974, 54 (02) :185-193
[3]  
COOK RP, 1958, CHOLESTEROL, P117
[4]  
HENRY RJ, 1964, CLIN CHEM PRINCIPLES, P843
[5]  
HEWITT D, 1977, CAN MED ASSOC J, V117, P1020
[6]   PROGRESS IN ANALYSIS OF LIPIDS .13. GAS-CHROMATOGRAPHY .5. [J].
KUKSIS, A .
FETTE SEIFEN ANSTRICHMITTEL, 1973, 75 (09) :517-533
[7]   IDENTIFICATION OF PLANT STEROLS IN PLASMA AND RED BLOOD-CELLS OF MAN AND EXPERIMENTAL-ANIMALS [J].
KUKSIS, A ;
MARAI, L ;
MYHER, JJ ;
GEHER, K .
LIPIDS, 1976, 11 (08) :581-586
[8]  
KUKSIS A, 1969, J LIPID RES, V10, P660
[9]  
KUKSIS A, 1967, J LIPID RES, V8, P352
[10]   DIRECT GAS CHROMATOGRAPHIC FRACTIONATION OF MIXED NEUTRAL LIPIDS OF NATURAL ORIGIN [J].
KUKSIS, A .
CANADIAN JOURNAL OF BIOCHEMISTRY AND PHYSIOLOGY, 1964, 42 (03) :419-&