DISTORTION-PRODUCT EMISSIONS AND AUDITORY-SENSITIVITY IN HUMAN EARS WITH NORMAL HEARING AND COCHLEAR HEARING-LOSS

被引:89
作者
NELSON, DA
KIMBERLEY, BP
机构
[1] Department of Otolaryngology, University of Minnesota, Box 396 UMHC, Minneapolis
来源
JOURNAL OF SPEECH AND HEARING RESEARCH | 1992年 / 35卷 / 05期
关键词
DISTORTION-PRODUCT OTOACOUSTIC EMISSIONS; HEARING LOSS; DPE THRESHOLDS; HEARING SCREENING;
D O I
10.1044/jshr.3505.1142
中图分类号
H [语言、文字];
学科分类号
05 ;
摘要
Distortion product emissions (DPEs) at 2f1-f2 frequencies were measured in 53 human ears; 21 of them exhibited cochlear hearing loss. DPEs were obtained as a function of stimulus level (DPE growth curves) at seven frequency regions between 707 Hz and 5656 Hz. Several distinctly different shapes or patterns of DPE growth curves were observed. These included single-segment monotonic growth curves with and without saturation at moderate and high stimulus levels, diphasic growth curves with nulls at moderate stimulus levels, and nonmonotonic growth curves with negative slopes at high stimulus levels. Low-level, irregularly shaped segments were more frequent in normal-hearing ears, suggestive of normal low-level active nonlinearities from the outer-hair-cell subsystem. High-level, steeply sloped segments were frequent in hearing-impaired ears, suggestive of residual nonlinearities from a cochlear partition without functional outer hair cells. The stimulus level at which the DPE could just be distinguished from the noise floor, the DPE detection threshold, demonstrated moderate positive correlations (r's from 0.50 to 0.81) with auditory thresholds when all ears, both normal and impaired, were considered together. Those correlations were not strong enough to quantitatively predict auditory thresholds with any great accuracy. However, DPE thresholds were able to predict abnormal auditory sensitivity with some precision. DPE thresholds correctly predicted abnormal auditory sensitivity 79% of the time in the present study, and up to 96% of the time in previous studies. These results suggest that DPE thresholds may prove useful for hearing screening in cases where cooperation from the subject is limited or where corroboration of cochlear hearing loss is required. Different patterns of DPE growth curves suggest underlying micro-mechanical differences between ears, but the differential diagnostic value of those patterns remains to be determined.
引用
收藏
页码:1142 / 1159
页数:18
相关论文
共 56 条
[1]  
American National Standards Institute, 1969, SPEC AUD
[2]   ACOUSTIC DISTORTION PRODUCTS CAN BE USED TO MONITOR THE EFFECTS OF CHRONIC GENTAMICIN TREATMENT [J].
BROWN, AM ;
MCDOWELL, B ;
FORGE, A .
HEARING RESEARCH, 1989, 42 (2-3) :143-156
[3]   SUPPRESSIBILITY OF THE 2F1-F2 STIMULATED ACOUSTIC EMISSIONS IN GERBIL AND MAN [J].
BROWN, AM ;
KEMP, DT .
HEARING RESEARCH, 1984, 13 (01) :29-37
[4]   MEASUREMENT OF ACOUSTIC DISTORTION REVEALS UNDERLYING SIMILARITIES BETWEEN HUMAN AND RODENT MECHANICAL RESPONSES [J].
BROWN, AM ;
GASKILL, SA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (02) :840-849
[6]  
BURNS JEM, 1984, HEARING RES, V19, P191
[7]  
DALLOS P, 1980, PSYCHOL PHYSL STUDIE
[8]   SHORT-TERM EFFECTS OF SOUND EXPOSURE ON THE 2F1-F2 ACOUSTIC-EMISSION [J].
DOLAN, TG ;
ABBAS, PJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (04) :1614-1616
[9]  
FAHEY P, 1986, PERIPHERAL AUDITORY
[10]   EAR CANAL ACOUSTIC DISTORTION AT 2F1-F2 FROM HUMAN EARS - RELATION TO OTHER EMISSIONS AND PERCEIVED COMBINATION TONES [J].
FURST, M ;
RABINOWITZ, WM ;
ZUREK, PM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (01) :215-221