PROTON THERAPY IN COMBINATION WITH PET AS MONITOR - A FEASIBILITY STUDY

被引:50
作者
PAANS, AMJ [1 ]
SCHIPPERS, JM [1 ]
机构
[1] KERNFYS VERSNELLER INST,9747 AA GRONINGEN,NETHERLANDS
关键词
D O I
10.1109/23.256709
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
To evaluate the possibility of combining proton therapy with Positron Emission Tomography (PET) as a therapy monitor and as a tool for in situ dosimetry during therapy, proton activiation experiments have been performed using a 55 MeV proton beam on two different materials. The 3-D measurements of the induced activity with PET are compared with the calculated dose distribution and with model calculations.
引用
收藏
页码:1041 / 1044