ISOTOPE RATIO MEASUREMENTS USING GLOW-DISCHARGE MASS-SPECTROMETRY

被引:19
作者
RICIPUTI, LR [1 ]
DUCKWORTH, DC [1 ]
BARSHICK, CM [1 ]
SMITH, DH [1 ]
机构
[1] OAK RIDGE NATL LAB,DIV CHEM & ANALYT SCI,OAK RIDGE,TN 37831
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1995年 / 146卷
关键词
GLOW DISCHARGE MASS SPECTROMETRY; ISOTOPE RATIOS;
D O I
10.1016/0168-1176(95)04203-W
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Glow discharge mass spectrometry (GDMS) has been evaluated for its ability to measure isotope ratios in solids. Isotope ratios were measured for B, Cu, Sr, Ag, Sb, Re and Pb in concentrations ranging from 15 ppm to pure metal. External precision of better than 0.03% has been achieved for isotope ratios measured using pure solid elemental samples; typical precision is better than 0.1% for elements present in concentrations greater than 0.5 wt.%. For elements present in concentrations of 10-20 ppm, precision was about 1%. Isotopic bias was < 1%, and day-to-day variations in isotopic bias for a single element are as large as variations in isotopic bias between different elements, suggesting that most isotopic bias is dominated by instrumental parameters. Values of isotope ratios show a dependence on the pressure of the Ar discharge gas, suggesting that improvements in sample geometry and discharge stability have the potential to allow GDMS to achieve even better precision in the measurement of isotope ratios.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 8 条
[1]   ROLE OF ISOTOPE MASS-SPECTROMETRY IN COSMIC ABUNDANCE STUDIES [J].
DELAETER, JR .
MASS SPECTROMETRY REVIEWS, 1994, 13 (01) :3-22
[2]   ISOTOPIC MEASUREMENTS OF PALLADIUM METAL CONTAINING PROTIUM AND DEUTERIUM BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DONOHUE, DL ;
PETEK, M .
ANALYTICAL CHEMISTRY, 1991, 63 (07) :740-744
[3]   DIRECT MEASUREMENT OF URANIUM ISOTOPIC-RATIOS IN SOILS BY GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
BARSHICK, CM ;
BOSTICK, DA ;
SMITH, DH .
APPLIED SPECTROSCOPY, 1993, 47 (02) :243-245
[4]   GLOW-DISCHARGE MASS-SPECTROMETRY - AN INTRODUCTION TO THE TECHNIQUE AND ITS UTILITY [J].
KING, FL ;
HARRISON, WW .
MASS SPECTROMETRY REVIEWS, 1990, 9 (03) :285-317
[5]   ISOTOPIC RATIO MEASUREMENTS WITH AN INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETER [J].
RUSS, GP ;
BAZAN, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :49-62
[6]  
RUSS GP, 1989, APPLICATIONS INDUCTI
[7]   ISOTOPIC RATIO MEASUREMENT USING A DOUBLE FOCUSING MAGNETIC-SECTOR MASS ANALYZER WITH AN INDUCTIVELY COUPLED PLASMA AS AN ION-SOURCE [J].
WALDER, AJ ;
FREEDMAN, PA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :571-575
[8]   ISOTOPE RATIO MEASUREMENT BY INDUCTIVELY-COUPLED PLASMA MULTIPLE COLLECTOR MASS-SPECTROMETRY INCORPORATING A HIGH-EFFICIENCY NEBULIZATION SYSTEM [J].
WALDER, AJ ;
KOLLER, D ;
REED, NM ;
HUTTON, RC ;
FREEDMAN, PA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (07) :1037-1041