DETERMINATION OF OXIDIZED, REDUCED AND PROTEIN-BOUND GLUTATHIONE IN EYE LENSES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION

被引:16
作者
OZCIMDER, M [1 ]
LOUTER, AJH [1 ]
LINGEMAN, H [1 ]
VOOGT, WH [1 ]
FREI, RW [1 ]
BLOEMENDAL, M [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT GEN & ANALYT CHEM,DE BOELELAAN 1083,1081 HV AMSTERDAM,NETHERLANDS
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 570卷 / 01期
关键词
D O I
10.1016/0378-4347(91)80197-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the detection of oxidized, reduced and protein-bound glutathione in eye lenses has been developed. Homogenized lens samples are deproteinated with acetonitrile and perchloric acid. Protein-bound glutathione is reduced by 1,4-dithiothreitol. Separation of the different forms of glutathione and dithiothreitol is performed by ion-pair reversed-phase high-performance liquid chromatography with sodium octylsulphate as the ion-pairing agent. The compounds are detected amperometrically using on-line-generated bromine, which oxidizes thiols and disulphides. In this way two samples can be analysed in triplicate in a single day. The lower detection limits are 80 and 48 nmol per gram wet lens for reduced and oxidized glutathione, respectively. The amounts of free reduced and protein-bound glutathione in calf lenses, determined with this method, are 6.8 +/- 0.4 and 0.96 +/- 0.03-mu-mol per gram wet lens; respectively. That of oxidized glutathione is less than 0.048-mu-mol per gram wet lens.
引用
收藏
页码:19 / 28
页数:10
相关论文
共 24 条
[1]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[2]   DETECTION OF OXIDIZED AND REDUCED GLUTATHIONE WITH A RECYCLING POSTCOLUMN REACTION [J].
ALPERT, AJ ;
GILBERT, HF .
ANALYTICAL BIOCHEMISTRY, 1985, 144 (02) :553-562
[3]  
Bloemendal H, 1981, MOL CELLULAR BIOL EY, P1
[4]   HPLC ANALYSIS OF LENS GSH AND GSSG [J].
CHANEY, WG ;
SPECTOR, A .
CURRENT EYE RESEARCH, 1984, 3 (02) :345-350
[5]   SIMULTANEOUS DETERMINATION OF GLUTATHIONE, GLUTATHIONE DISULFIDE, PARACETAMOL AND ITS SULFUR-CONTAINING METABOLITES USING HPLC AND ELECTROCHEMICAL DETECTION WITH ONLINE GENERATED BROMINE [J].
DEBETS, AJJ ;
VANDESTRAAT, R ;
VOOGT, WH ;
VOS, H ;
VERMEULEN, NPE ;
FREI, RW .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (03) :329-336
[6]   MEASUREMENT OF TISSUE SULFHYDRYLS AND DISULFIDES IN TISSUE PROTEIN AND NONPROTEIN FRACTIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ELECTROCHEMICAL DETECTION [J].
DUPUY, D ;
SZABO, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (01) :107-119
[7]  
GELATT KN, 1982, AM J VET RES, V43, P1215
[8]  
HARDING J, 1970, BIOCHEM J, V114, P88
[9]   ENZYMATIC DETERMINATION OF REDUCED AND OXIDIZED GLUTATHIONE IN BOVINE LENSES OF DIFFERENT AGES AND THEIR DISTRIBUTION IN LENS EQUATOR AND NUCLEUS [J].
HATA, N ;
HOCKWIN, O .
OPHTHALMIC RESEARCH, 1977, 9 (04) :256-262
[10]   THE IMPORTANCE OF MEMBRANE SULFHYDRYL-GROUPS TO CALCIUM HOMEOSTASIS IN THE LENS [J].
HIGHTOWER, KR .
CURRENT EYE RESEARCH, 1985, 4 (08) :857-865