DIODE DOSIMETRY OF MODEL-6711 AND MODEL-6712 I-125 SEEDS IN A WATER PHANTOM

被引:9
作者
AHMAD, M
FONTENLA, DP
TSAO, STC
CHUI, CS
REIFF, JE
ANDERSON, LL
HUANG, DYC
SCHELL, MC
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT MED PHYS,NEW YORK,NY 10021
[2] UNIV CALIF SAN FRANCISCO,DEPT RADIAT ONCOL,SAN FRANCISCO,CA 94143
关键词
BRACHYTHERAPY; DOSIMETRY; I-125; SEEDS; SILICON DIODE;
D O I
10.1118/1.596872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional relative dose distributions have been measured around I-125 brachytherapy seeds. The two seed models studied, models 6711 and 6712, were manufactured by the 3M Company. Silicon detectors immersed in water phantoms were used to measure the dose. A computerized data acquisition system that controlled the radial position of the diode and the angular rotation of the seed, as well as a manually controlled system were used to collect and store the data. Our results show that the two seed models have relative dose distributions which are quite similar; however, the absolute dose distributions are sufficiently different to warrant separate look-up tables for the two seed models. Additionally, our results are compared with dose distribution data previously obtained for the model 6711 seed.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 25 条
[1]  
Anderson LL, 1990, INTERSTITIAL BRACHYT
[2]  
Blasko JC, 1987, ENDOCURIETHER HYPERT, V3, P131
[3]   CHOROIDAL MELANOMA - I125 PLAQUE THERAPY [J].
BOSWORTH, JL ;
PACKER, S ;
ROTMAN, M ;
HO, T ;
FINGER, PT .
RADIOLOGY, 1988, 169 (01) :249-251
[4]   TWO-DIMENSIONAL DOSE DISTRIBUTION AROUND A COMMERCIAL I125 SEED [J].
BURNS, GS ;
RAESIDE, DE .
MEDICAL PHYSICS, 1988, 15 (01) :56-60
[5]   DOSE-RATE DETERMINATION FOR I-125 SEEDS [J].
CHIUTSAO, ST ;
ANDERSON, LL ;
OBRIEN, K ;
SANNA, R .
MEDICAL PHYSICS, 1990, 17 (05) :815-825
[6]  
CHIUTSAO ST, 1986, MED PHYS, V13, P784
[7]   THE CLINICAL ADVANTAGES OF I125 SEEDS AS A SUBSTITUTE FOR IR-192 SEEDS IN TEMPORARY PLASTIC TUBE IMPLANTS [J].
CLARKE, DH ;
EDMUNDSON, GK ;
MARTINEZ, A ;
MATTER, RC ;
VICINI, F ;
SEBASTIAN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (04) :859-863
[8]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[10]   LUNG-TUMORS - PERCUTANEOUS IMPLANTATION OF I-125 SOURCES WITH CT TREATMENT PLANNING [J].
HEELAN, RT ;
HILARIS, BS ;
ANDERSON, LL ;
NORI, D ;
MARTINI, N ;
WATSON, RC ;
CARAVELLI, JF ;
LINARES, LA .
RADIOLOGY, 1987, 164 (03) :735-740