摘要
Ro 23-7637 (1) is a new drug under development for the treatment of metabolic diseases. A high-performance liquid chromatographic-ultraviolet detection (HPLC-UV) analytical procedure for its analysis in dog plasma was developed and is reported here. Following C18 solid-phase extraction, the sample is applied to a strong cation-exchange column in the first dimension. The analyte and intemal standard, Ro 24-4558 (II), are transferred to a base-deactivated C18 reversed-phase column in the second dimension (orthogonal separation mechanism), with UV detection at 254 nm. The reversed-phase solid-phase extraction provides a gross isolation of the drug, based on hydrophobicity. The first-dimension ion-exchange separation allows neutral species and anions to elute with the column void volume, while separating basic species according to pK(a). The second dimension provides a high-resolution separation dependent upon the hydrophobicity of the sample species. The rationale for using orthogonal multidimensional chromatography was that an exhaustive examination of reversed-phase and normal-phase columns invariably resulted in co-elution of I with endogenous plasma components, which limited the sensitivity of the method. We have utilized C18 solid-phase extraction, followed by multidimensional HPLC-UV, to develop an accurate and precise analytical method whose limit of quantitation, 5 ng/ml using 0.5 ml of plasma, is determined by inherent detector sensitivity. Increased sensitivity can be readily achieved by using more sample or by using microbore HPLC on the second dimension.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 20 条
[1]   A DUAL-COLUMN HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF DHPG (9-[(1,3-DIHYDROXY-2-PROPOXY)METHYL]GUANINE) AND ITS MONO AND DIESTERS IN BIOLOGICAL SAMPLES [J].
BENJAMIN, EJ ;
FIRESTONE, BA ;
SCHNEIDER, JA .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (04) :168-170
[2]   AUTOMATED LIQUID-CHROMATOGRAPHIC ANALYSIS OF DRUGS IN URINE BY ONLINE SAMPLE CLEANUP AND ISOCRATIC MULTICOLUMN SEPARATION [J].
BINDER, SR ;
REGALIA, M ;
BIAGGIMCEACHERN, M ;
MAZHAR, M .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02) :325-341
[3]   PRECOLUMN-VENTING PLUG TECHNIQUE FOR DIRECT INJECTION OF UNTREATED BLOOD-PLASMA SAMPLES INTO REVERSED-PHASE LIQUID-CHROMATOGRAPHY SYSTEMS [J].
DAOUD, N ;
ARVIDSSON, T ;
WAHLUND, KG .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :311-322
[4]   DIRECT DETERMINATION OF DEBRISOQUINE AND 4-HYDROXYDEBRISOQUINE USING A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SWITCHING TECHNIQUE [J].
DECOLIN, D ;
NICOLAS, A ;
MOTASSIM, N ;
SIEST, G .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :469-474
[5]   MICROMETHOD FOR THE DETERMINATION OF CEFPIRAMIDE IN HUMAN-PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING [J].
DEMOTESMAINARD, F ;
VINCON, G ;
JARRY, C ;
NECCIARI, J ;
ALBIN, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :388-395
[6]   IMMUNOAFFINITY PRE-COLUMN FOR SELECTIVE ONLINE SAMPLE PRE-TREATMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION OF 19-NORTESTOSTERONE [J].
FARJAM, A ;
DEJONG, GJ ;
FREI, RW ;
BRINKMAN, UAT ;
HAASNOOT, W ;
HAMERS, ARM ;
SCHILT, R ;
HUF, FA .
JOURNAL OF CHROMATOGRAPHY, 1988, 452 :419-433
[7]   ULTRASELECTIVITY THROUGH COLUMN SWITCHING AND MODE SEQUENCING IN LIQUID-CHROMATOGRAPHY - REVIEW [J].
FREEMAN, DH .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :2-5
[8]   TRACE-LEVEL DETERMINATION OF 3'-AZIDO-3'-DEOXYTHYMIDINE IN HUMAN-PLASMA BY PRECONCENTRATION ON A SILVER(I)-THIOL STATIONARY PHASE WITH ONLINE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IRTH, H ;
TOCKLU, R ;
WELTEN, K ;
DEJONG, GJ ;
BRINKMAN, UAT ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (02) :321-330
[9]   DETERMINATION OF ATENOLOL IN PLASMA BY DUAL-COLUMN LIQUID-CHROMATOGRAPHY AND FLUORIMETRIC DETECTION [J].
JOHANSSON, M ;
FORSMOBRUCE, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 432 :265-272
[10]   ANALYSIS OF 5-FLUOROURACIL IN PLASMA BY PRECOLUMN DERIVATIZATION WITH 4-BROMOMETHYL-7-METHOXYCOUMARIN, FOLLOWED BY MULTI-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KINDBERG, CG ;
RILEY, CM ;
STOBAUGH, JF ;
SLAVIK, M .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02) :431-444