Pilot plant evaluation of advanced vs conventional scale inhibitors for RO desalination

被引:41
作者
Butt, FH
Rahman, F
Baduruthamal, U
机构
[1] Research Institute, King Fahd University of Petroleum and Minerals, Dhaharan
关键词
desalination; RO; scaling; scale inhibitors;
D O I
10.1016/0011-9164(95)00072-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An advanced anti-sealant, consisting of a polyacrylate and hydroxyethylidene diphosphonate (HEDP), was tested against the conventional H2SO4 and sodium hexa-meta-phosphate (SHMP) inhibitors in a pilot plant which had parallel RO units. The two units were fitted with identical brackish hollow fine fiber (HFF) permeators arranged in a two-stage mode which received the same brackish feed water, and were operated at the same feed pressure (27.6 bar/400 psig) and product water recovery (70%). Unit #1 was treated with 9 ppm of as-received advanced anti-sealant, and unit #2 was treated with 6 ppm of SHMP and about 130 ppm of 98% H2SO4. The pilot plant trial lasted for 3,000 h. The techno-economic evaluation of the two scale control treatments was carried out in terms of pumping energy, the anti-sealants consumed, and the quality and total output of the product water produced in 3,000 h. The pumping energy and scale control treatment costs (as $/m(33) of water produced) were same for the two treatments; but in terms of salt rejection, product TDS and output, performance of the advanced anti-sealant was inferior; after 3,000 h the salt rejection of unit #1 (which operated on the advanced anti-sealant) was about 81% vs. 94% for unit #2 (H(2)SO(4)(+)SHMP). Similarly, in 3,000 h unit #1 produced 20% less water of unacceptable quality (620 ppm) whereas unit #2 produced more water of excellent quality (180 ppm), providing a dear testimony to the superior performance of the conventional H2SO4+SHMP treatment over the advanced anti-sealant.
引用
收藏
页码:189 / 198
页数:10
相关论文
共 12 条
[1]   PRETREATMENT AND CLEANING OF HYPERFILTRATION (REVERSE-OSMOSIS) MEMBRANES IN MUNICIPAL WASTEWATER RENOVATION [J].
BELFORT, G .
DESALINATION, 1977, 21 (03) :285-300
[2]  
Cowan J., 1976, WATER FORMED SCALE D, P269
[3]  
FRANGIPANE M., 1985, STANDARD METHODS EXA, P215
[4]  
HATCH RT, 1984, 12TH WAT SUPPL IMPR, P85
[5]   THE APPLICATION OF A NOVEL CHEMICAL TREATMENT PROGRAM TO MITIGATE SCALING AND FOULING IN REVERSE-OSMOSIS UNITS [J].
JAFFER, AE .
DESALINATION, 1994, 96 (1-3) :71-79
[6]  
JOHNSON WE, 1981, ROCK MINERAL ANAL, P263
[7]  
Loeb S., 1967, DESALINATION, V2, P75, DOI [10.1016/S0011-9164(00)80147-2, DOI 10.1016/S0011-9164(00)80147-2]
[8]  
REITZ RL, 1984, 12TH P WAT SUPPL IMP, P39
[9]  
SMITH AL, 1985, DESALINATION, V55, P277
[10]  
1992, PERMASEP ENG MANUAL