USE OF END-TIDAL CARBON-DIOXIDE TO PREDICT OUTCOME IN PREHOSPITAL CARDIAC-ARREST

被引:93
作者
WAYNE, MA
LEVINE, RL
MILLER, CC
机构
关键词
D O I
10.1016/S0196-0644(95)70204-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: End-tidal CO2 (ETCO(2)) measurement can be used to predict death in prehospital cardiac arrest patients with pulseless electrical activity (PEA). Design: A prospective, observational study. Setting: An urban and rural emergency medical services system in northwestern Washington state. Participants: Ninety consecutive victims of prehospital cardiac arrest with PEA. Interventions: Patients were intubated in the field and treated using standard advanced cardiac life support protocols with on-line medical control. In addition, all patients were evaluated using mainstream ETCO(2) monitoring. In this study, a hypothetical decision was made to cease resuscitative efforts based on an ETCO(2) level of 10 mm Hg or less after 20 minutes of advanced cardiac life support. Results: The study included 90 patients (61 were men) with a mean age of 67.6 +/- 13.6 years (range, 27 to 95 years). The initial ETCO(2) averaged 11.7 +/- 6.6 mm Hg in nonsurvivors (range, 5 to 50 mm Hg) and 10.9 +/- 4.9 mm Hg in survivors (range, 5 to 24 mm Hg) (P >.672 [NS]). After 20 minutes of advanced cardiac life support, ETCO(2), averaged 3.9 +/- 2.8 mm Hg (range, 0 to 12 mm Hg) in patients in whom the theoretical decision was made to cease field resuscitation. In contrast, survivors' ETCO(2), just before restoration of circulation, averaged 31 +/- 5.3 mm Hg (range, 16 to 35 mm Hg) (P<.0001). Using an ETCO(2) of 10 mm Hg or less as a theoretical threshold to predict death in the field successfully discriminated between the 16 survivors to hospital admission (those that achieved return of spontaneous circulation) and 75 prehospital deaths. Of the 16 survivors to hospital admission, 9 died in the hospital, and 7 were discharged from the hospital alive. In 13 of the 16 survivors, the first evidence of return of spontaneous circulation, before a palpable pulse or blood pressure, was a rising ETCO(2). The logistic-regression parameters for the model are 4.4391 + ETCO(2)*-0.3624 (P<.0001). Sensitivity was 97.3%; specificity 100%; positive predictive value 100%; and negative predictive value 88.9%. Conclusion: This study suggests that a low ETCO(2) (10 mm Hg or less) can be used to predict irreversible death in patients with pulseless electrical activity undergoing prehospital advanced cardiac life support. if future studies validate this model, use of ETCO(2) may allow for triage decisions in the field.
引用
收藏
页码:762 / 767
页数:6
相关论文
共 44 条
[1]  
Weaver, Cobb, Hallstrom, Et al., Considerations for improving survival from out-of-hospital cardiac arrest, Annals of Emergency Medicine, 15, pp. 1181-1186, (1986)
[2]  
Aprahamian, Thompson, Gruchow, Et al., Decision making in prehospital sudden cardiac arrest, Ann Emerg Med, 15, pp. 445-449, (1986)
[3]  
Myerburg, Kessler, Zaman, Et al., Survivors of prehospital cardiac arrest, JAMA, 247, pp. 1485-1490, (1982)
[4]  
Eisenberg, Horwod, Cummins, Et al., Cardiac arrest and resuscitation: A tale of 29 cities, Ann Emerg Med, 19, pp. 179-186, (1990)
[5]  
Gray, Capone, Most, Unsuccessful emergency medical resuscitation - are continued efforts in the emergency department justified?, N Engl J Med, 325, pp. 1393-1398, (1991)
[6]  
Bonnin, Pepe, Kimball, Et al., Distinct criteria for termination of resuscitation in out-of-hospital setting, JAMA, 270, pp. 1457-1462, (1993)
[7]  
Gray, Prehospital resuscitation: The good, the bad, and the futile, JAMA, 270, pp. 1471-1472, (1993)
[8]  
Iris, Staples, O'Brien, Et al., End-tidal carbon dioxide during extremely low cardiac output, Annals of Emergency Medicine, 23, pp. 568-572, (1994)
[9]  
Weil, Bisera, Trevino, Et al., Cardiac output and end-tidal carbon dioxide, Critical Care Medicine, 13, pp. 907-909, (1984)
[10]  
Gudipati, Weil, Bisera, Et al., Expired carbon dioxide: A non-invasive monitor of cardiopulmonary resuscitation, Circulation, 77, pp. 234-239, (1988)