BIOMECHANICS OF LUMBAR PEDICLE SCREW PLATE FIXATION IN TRAUMA

被引:34
作者
YOGANANDAN, N [1 ]
LARSON, SJ [1 ]
PINTAR, F [1 ]
MAIMAN, DJ [1 ]
REINARTZ, J [1 ]
SANCES, A [1 ]
机构
[1] DEPT VET AFFAIRS MED CTR,MILWAUKEE,WI
关键词
Biomechanics; Compression-flexion; Fusion; Spinal trauma; Spine stabilization;
D O I
10.1227/00006123-199012000-00003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This investigation was conducted to determine alterations in the biomechanical strength and stiffness characteristics of the lumbar spine fixated with Steffee instrumentation. Comparative studies of these parameters were conducted using seven lumbar columns from fresh human cadavers. Three runs were conducted on each T12-L5 column: control, injured, and fixated. The specimens were loaded under the compression-flexion mode until failure (control run) and then reloaded (injury run) to the failure deformation determined in the control run. Screw/plates were then inserted one level proximal and distal to injury, and the specimens were reloaded (fixation run). Radiographs were taken before and after each trial. Data on deformation and force histories were gathered. The load-deflection response of the injured and fixated specimens were bimodal with two representative stiffnesses. Control failure loads and stiffnesses were higher than those for the injured (P < 0.001) or fixated (P < 0.01) spine. Initial stiffness was significantly higher for the fixated than for injured columns (P < 0.001), but the final stiffnesses were similar. The increase in the initial stiffness in the fixated specimen compared to the injured specimen indicates the strength added to the posterior region of the spine. The relatively smaller alteration in the final stiffness between the fixated and the injured columns, corresponding to the load shared by the anterior column, may suggest that, above a critical strain level, the anterior column absorbs a higher portion of the external load and posterior fixation may be inadequate as sole treatment in trauma.
引用
收藏
页码:873 / 881
页数:9
相关论文
共 25 条
[1]   BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL [J].
ASHMAN, RB ;
GALPIN, RD ;
CORIN, JD ;
JOHNSTON, CE .
SPINE, 1989, 14 (12) :1398-1405
[2]  
CHANG KW, 1989, J SPINAL DISORD, V1, P257
[3]   BIOMECHANICS OF CERVICAL-SPINE FACETECTOMY AND FIXATION TECHNIQUES [J].
CUSICK, JF ;
YOGANANDAN, N ;
PINTAR, F ;
MYKLEBUST, J ;
HUSSAIN, H .
SPINE, 1988, 13 (07) :808-812
[5]   THE FIXATUER-INTERNE AS A VERSATILE IMPLANT FOR SPINE SURGERY [J].
DICK, W .
SPINE, 1987, 12 (09) :882-900
[6]   THE AO SPINAL INTERNAL FIXATOR [J].
ESSES, SI .
SPINE, 1989, 14 (04) :373-378
[7]   BIOMECHANICAL ANALYSIS OF ANTERIOR AND POSTERIOR INSTRUMENTATION SYSTEMS AFTER CORPECTOMY - A CALF-SPINE MODEL [J].
GURR, KR ;
MCAFEE, PC ;
SHIH, CM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) :1182-1192
[8]   BIOMECHANICAL ANALYSIS OF POSTERIOR INSTRUMENTATION SYSTEMS AFTER DECOMPRESSIVE LAMINECTOMY - AN UNSTABLE CALF-SPINE MODEL [J].
GURR, KR ;
MCAFEE, PC ;
SHIH, CM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05) :680-691
[9]  
HERRING JA, 1986, 21ST P ANN SCOL RES
[10]   THE WILTSE PEDICLE SCREW FIXATION SYSTEM - EARLY CLINICAL-RESULTS [J].
HOROWITCH, A ;
PEEK, RD ;
THOMAS, JC ;
WIDELL, EH ;
DIMARTINO, PP ;
SPENCER, CW ;
WEINSTEIN, J ;
WILTSE, LL .
SPINE, 1989, 14 (04) :461-467