THE REFERENCE MAN IN DIAGNOSTIC-RADIOLOGY DOSIMETRY

被引:48
作者
LINDSKOUG, BA
机构
[1] Dept. Radiation and Hospital Physics
关键词
DIAGNOSTIC RADIOLOGY; DOSIMETRY; REFERENCE MAN; DETRIMENTAL EFFECTS;
D O I
10.1259/0007-1285-65-773-431
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Following the legislation for radiation protection in Europe, increasing interest has been given to patient dosimetry in diagnostic radiology. Dose comparisons between groups of patients have demonstrated considerable discrepancies. The equipment, as well as the procedures used, have been scrutinized in order to find the reasons for the variation and to reduce it. In this work. patient size and shape are considered in patient dose evaluations in diagnostic radiology. The size. shape and constitution of the patients are shown to relate exponentially to the energy imparted during examination of the trunk. The equivalent cylindrical diameter of the patient body is used as the independent variable. Exponential functions are created by linear regression. The ICRP Reference Man with an equivalent diameter of 22.9 cm is used as a body-size standard. A method is suggested by which coordinate transformations reduce data to a base line defined by the Reference Man. It is shown that the method reduces the range of energy imparted by between 30% and 60% for six common X-ray examinations of the trunk. Resulting data constitute a finer instrument for intercomparisons between hospitals for the same examination. Further, it is suggested that adipose tissues should not be included when detrimental effects of radiologic exposure arc determined. The Reference Man, stripped of 10 kg subcutaneous adipose tissue, is used as the non-fat standard dimension corresponding to the equivalent cylindrical diameter 21.2 cm. The suggested method is used to estimate the fraction of energy imparted to vital organs only. The results show that the energy imparted is reduced by between 30% and 60% according to this model. Consequently, predicted deaths are reduced by the same amount.
引用
收藏
页码:431 / 437
页数:7
相关论文
共 10 条
[1]   PATIENT EXPOSURES AND RADIATION RISKS IN SWEDISH DIAGNOSTIC RADIOLOGY [J].
BENGTSSON, G ;
BLOMGREN, PG ;
BERGMAN, K ;
ABERG, L .
ACTA RADIOLOGICA ONCOLOGY, 1978, 17 (02) :81-105
[2]   ENERGY IMPARTED TO THE PATIENT IN DIAGNOSTIC-RADIOLOGY - CALCULATION OF CONVERSION FACTORS FOR DETERMINING THE ENERGY IMPARTED FROM MEASUREMENTS OF THE AIR COLLISION KERMA INTEGRATED OVER BEAM AREA [J].
CARLSSON, GA ;
CARLSSON, CA ;
PERSLIDEN, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1329-1341
[3]  
JONES DG, 1985, NRPB186 REP
[4]  
MOORE BM, 1989, CEC BIR20 BRIT I RAD
[5]  
MOORES BM, 1987, ADV SEMINAR DIAGNOST
[6]  
MORRES BM, 1989, TECHNICAL PHYSICAL P, P81
[7]  
SHRIMPTON PC, 1989, 4TH P INT S SRP MALV
[8]  
1975, PUBLICATION ICRP, V23
[9]  
1991, IN PRESS SEMINAR DOS
[10]  
1990, DOCUMENTS NRPB, V1