NEW DESIGN FOR FOURIER-TRANSFORM INFRARED VIBRATIONAL CIRCULAR-DICHROISM SPECTROMETERS

被引:12
作者
CHEN, GC
POLAVARAPU, PL
WEIBEL, S
机构
[1] VANDERBILT UNIV,DEPT CHEM,NASHVILLE,TN 37235
[2] ATI INSTRUMENTS NA,MADISON,WI 53717
关键词
VIBRATIONAL CIRCULAR DICHROISM; CYCLODEXTRINS; PHASE CORRECTION;
D O I
10.1366/0003702944027499
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fourier transform infrared (FT-IR) spectrometers are commonly designed with small-area detectors and tight focusing mirrors. Vibrational circular dichroism (VCD) measurements made with such FT-IR instruments contain polarization artifacts, and VCD measurements on both enantiomers (or one enantiomer and racemic mixture) are required in order to reduce these artifacts. This restriction limits the VCD measurements to only those samples for which both enantiomers (or one enantiomer and racemic mixture) are available. Recently a modified design was reported in the literature where the mirrors between sample and detector were replaced with a BaF2 lens, and a larger-area detector was substituted for the smaller-area counterpart. These modifications successfully alleviated some of the artifact problems. This design, however, is not suitable for polarizing interferometers, where polarizations exiting the interferometer are to be preserved to a high degree of purity. In addition, it is not clear whether the throughput enhancement advantage realized with a larger-area detector completely offsets the disadvantage from increased noise with detector area. Furthermore, BaF, lenses reduce the broad range routinely available on an FT-IR instrument. Here we report a new design that replaces all the mirrors at the exit port of the interferometer with two KBr lenses and retains the full spectral range (4000-400 cm(-1)) of mid-infrared FT-IR spectrometers. VCD measurements obtained with small-(1 x 1 mm) and large-(4 x 4 mm) area detectors are found to have similar signal quality.
引用
收藏
页码:1218 / 1223
页数:6
相关论文
共 23 条
[11]  
MARTIN DH, 1969, INFRARED PHYS, V10, P105, DOI DOI 10.1016/0020-0891(70)90006-0
[12]  
Nafie L. A., 1982, FOURIER TRANSFORM IN, V3, P83
[13]   VIBRATIONAL CIRCULAR-DICHROISM [J].
NAFIE, LA ;
KEIDERLING, TA ;
STEPHENS, PJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1976, 98 (10) :2715-2723
[14]   FOURIER-TRANSFORM INFRARED VIBRATIONAL CIRCULAR-DICHROISM [J].
NAFIE, LA ;
DIEM, M ;
VIDRINE, DW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1979, 101 (02) :496-498
[15]   CIRCULAR-DICHROISM IN THE FAR INFRARED AND MILLIMETER WAVELENGTH REGIONS - PRELIMINARY MEASUREMENTS [J].
POLAVARAPU, PL ;
QUINCEY, PG ;
BIRCH, JR .
INFRARED PHYSICS, 1990, 30 (02) :175-179
[16]   FAR INFRARED CIRCULAR-DICHROISM MEASUREMENTS WITH MARTIN-PUPLETT INTERFEROMETER - METHODS AND ANALYSIS [J].
POLAVARAPU, PL .
INFRARED PHYSICS, 1988, 28 (02) :109-112
[17]   NEW DEVELOPMENTS IN FOURIER-TRANSFORM INFRARED VIBRATIONAL CIRCULAR-DICHROISM MEASUREMENTS [J].
POLAVARAPU, PL .
APPLIED SPECTROSCOPY, 1989, 43 (08) :1295-1297
[18]   DEVELOPMENT, JUSTIFICATION, AND APPLICATIONS OF A MIDINFRARED POLARIZATION-DIVISION INTERFEROMETER [J].
POLAVARAPU, PL ;
CHEN, GC ;
WEIBEL, S .
APPLIED SPECTROSCOPY, 1994, 48 (10) :1224-1235
[19]   ON THE MEASUREMENT OF VIBRATIONAL CIRCULAR-DICHROISM OF A SINGLE ENANTIOMER ON FOURIER-TRANSFORM INFRARED SPECTROMETERS [J].
POLAVARAPU, PL ;
MICHALSKA, DF ;
BACK, DM .
APPLIED SPECTROSCOPY, 1984, 38 (03) :438-442
[20]  
Polavarapu PL, 1985, FOURIER TRANSFORM IN, V4, P61