RAPID 3-DIMENSIONAL SURFACE RECONSTRUCTION OF MAGNETIC-RESONANCE IMAGES OF LARGE ARTERIES AND VEINS - A PRELIMINARY EVALUATION OF CLINICAL UTILITY

被引:5
作者
KANDARPA, K
SANDOR, T
TIEMAN, J
HOOSHMAND, R
CHOPRA, PS
CHAKRABATI, J
机构
[1] Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts, 02115
关键词
3-DIMENSIONAL; MAGNETIC RESONANCE IMAGING; DISPLAY PROCESSING; VASCULAR SURFACE RENDERING;
D O I
10.1007/BF02603033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have implemented a computerized system for relatively rapid (< 1 h) three-dimensional (3D) surface rendering of flow-sensitive (gradient refocused) magnetic resonance images. The method has been applied in 8 patients with six different clinical problems and was found to enhance understanding of normal and abnormal aortic, caval, and portosystemic venous anatomy. 3D images are useful for communicating complex anatomic information and may help with difficult diagnoses. Advantages and limitations of the present system are discussed.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 23 条
[1]  
Fishman E.K., Magid D., Ney D.R., Chaney E.L., Pizer S.M., Rosenman J.G., Levin D.N., Vannier M.W., Kuhlman J.E., Robertson D.D., Three-dimensional imaging, Radiology, 181, pp. 321-327, (1991)
[2]  
Wallis J.W., Miller T.R., Three-dimensional display in nuclear medicine and radiology, J Nucl Med, 32, pp. 534-546, (1991)
[3]  
Hade J.D., Valk P.E., Watts J.C., Kaufman L., Crooks L.E., Higgins C.B., Deconinck F., MR imaging of blood vessels using three-dimensional reconstruction: Methodology, Radiology, 157, pp. 727-733, (1985)
[4]  
Valk P.E., Hale J.D., Kaufman L., Crooks L.E., Higgins C.B., MR imaging of the aorta with three-dimensional vessel reconstruction: Validation by angiography, Radiology, 157, pp. 721-725, (1985)
[5]  
Vannier M.W., Gutierrez F.R., Laschinger J.C., Three-dimensional magnetic resonance imaging, Top Magn Reson Imaging, 2, pp. 61-65, (1990)
[6]  
Rusinek H., Mourino, Firooznia H., Weinreb J.L., Chase N.E., Volumetric rendering of MR images, Radiology, 171, pp. 269-272, (1989)
[7]  
Levin D.N., Hu X., Tan K.K., Galhotra S., Surface of the brain: Three-dimensional MR images created with volume rendering, Radiology, 171, pp. 277-280, (1989)
[8]  
Defriese M., Townsend D., Geissbuhler A., Implementation of three-dimensional image reconstruction for multi-ring positron tomographs, Phys Med Biol, 35, pp. 1361-1372, (1990)
[9]  
Diaspro A., Adami M., Sartore M., Nicolini C., IMAGO: A complete system for acquisition, processing, two/three dimensional and temporal display of microscopic bio-images, Comput Methods Programs Bio-Med, 31, pp. 225-236, (1990)
[10]  
Stytz, Frieder O., Computer systems for three-dimensional diagnostic imaging: An examination of the state of the art, Crit Rev Biomed Engr, 19, pp. 1-45, (1991)