DETERMINATION OF ALBUTEROL CONCENTRATIONS IN HUMAN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:31
作者
BLAND, RE
TANNER, RJN
CHERN, WH
LANG, JR
POWELL, JR
机构
[1] GLAXO INC,PHARMACEUT DEV,DEPT CLIN PHARMACOKINET,5 MOORE DR,RES TRIANGLE PK,NC 27709
[2] GLAXO GRP RES LTD,DEPT BIOCHEM PHARMACOL,WARE SG12 0DJ,HERTS,ENGLAND
关键词
Albuterol; fluorescence detection; high-performance liquid chromatography; human plasma; pharmacokinetic studies; routine sample analysis; solid-phase extraction;
D O I
10.1016/0731-7085(90)80085-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, simple, and accurate method for determining albuterol concentrations in human plasma has been developed and validated for use in routine clinical analyses. This method involves a solid-phase extraction procedure using silica cartridges and normal-phase high-performance liquid chromatography with fluorescence detection. Regression analysis showed the method was linear over the standard curve range 1-16 ng ml-1. The percent recovery for albuterol and the internal standard, bamethane, at 5 ng ml-1 was found to be ≫90%. The newly developed method has been applied in the analysis of plasma samples from patients and healthy volunteers. © 1990.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 13 条
  • [1] AUTOMATED EXTRACTION OF DRUGS FROM BIOLOGICAL-FLUIDS
    BLAND, RE
    HARRISON, C
    MARTIN, LE
    OXFORD, J
    TANNER, RJN
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1984, 18 (1-2) : 25 - 35
  • [2] SALBUTAMOL - A NEW SELECTIVE BETA-ADRENOCEPTIVE RECEPTOR STIMULANT
    CULLUM, VA
    FARMER, JB
    JACK, D
    LEVY, GP
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1969, 35 (01) : 141 - &
  • [3] DETERMINATION OF ALBUTEROL IN HUMAN-SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    EMM, T
    LESKO, LJ
    LESLIE, J
    PERKAL, MB
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 427 (01): : 188 - 194
  • [4] FARMER JB, 1969, BRIT J PHARMACOL, V35, P358
  • [5] DETERMINATION OF SALBUTAMOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    HUTCHINGS, MJ
    PAULL, JD
    MORGAN, DJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1983, 277 (OCT): : 423 - 426
  • [6] LABORATORY AND CLINICAL-FEATURES OF SELF-POISONING WITH SALBUTAMOL AND TERBUTALINE
    JARVIE, DR
    THOMPSON, AM
    DYSON, EH
    [J]. CLINICA CHIMICA ACTA, 1987, 168 (03) : 313 - 322
  • [7] JENNE JW, 1987, DRUG THERAPY ASTHMA, V31, P213
  • [8] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF SALBUTAMOL IN RABBIT PLASMA
    KUROSAWA, N
    MORISHIMA, S
    OWADA, E
    ITO, K
    [J]. JOURNAL OF CHROMATOGRAPHY, 1984, 305 (02): : 485 - 488
  • [9] DETERMINATION OF SALBUTAMOL IN HUMAN-PLASMA WITH BIMODAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND A ROTATED DISK AMPEROMETRIC DETECTOR
    OOSTERHUIS, B
    VANBOXTEL, CJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 232 (02): : 327 - 334
  • [10] COMPARATIVE BIOAVAILABILITY AND PHARMACOKINETICS OF 3 FORMULATIONS OF ALBUTEROL
    POWELL, ML
    WEISBERGER, M
    GURAL, R
    CHUNG, M
    PATRICK, JE
    RADWANSKI, E
    SYMCHOWICZ, SS
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1985, 74 (02) : 217 - 219