ENERGY RESOLUTION TESTS OF 125 MM DIAMETER CYLINDRICAL NE213 DETECTOR USING MONOENERGETIC GAMMA-RAYS

被引:25
作者
NAQVI, AA
ALJUWAIR, H
GUL, K
机构
[1] Energy Research Laboratory, King Fahd University of Petroleum and Minerals, Dhahran
关键词
D O I
10.1016/0168-9002(91)90331-J
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Pulse height tests have been carried out for cylindrical NE213 liquid scintillation detectors of diameters 50 and 125 mm, using monoenergetic gamma rays. The 125 and 50 mm NE213 scintillator cells, each having a thickness of 50 mm, were directly coupled to 130 mm and 52 mm diameter photomultipliers respectively. Gamma-gamma coincidence technique was used to determine the detector's energy resolution and pulse height corresponding to the maximum energy of Compton electrons over the gamma rays energy range of 0.5-1.2 MeV. For the 125 mm detector, the energy corresponding to half height of Compton maxima is 14.4-6.6% higher than the maximum energy of Compton electrons while its energy resolution varies from 24.0 to 18.0%. For the 50 mm detector the energy corresponding to half height of Compton maxima is 9.8-4.0% higher than the maximum energy of Compton electrons while its energy resolution varies from 18.8 to 12.2%. For the 125 mm diameter detector results are presented for the first time.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 10 条
[1]   THE VAX 11/785 CLUSTER-BASED DATA ACQUISITION-SYSTEM AT THE KFUPM ENERGY RESEARCH LABORATORY [J].
ALJUWAIR, HA ;
ABDELAAL, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :611-614
[2]   ENERGY CALIBRATION OF NE-213 SCINTILLATION-COUNTERS BY GAMMA-RAYS [J].
DIETZE, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) :398-402
[3]   GAMMA-CALIBRATION OF NE-213 SCINTILLATION-COUNTERS [J].
DIETZE, G ;
KLEIN, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 193 (03) :549-556
[4]   THE PARAMETERS OF THE FULL ABSORPTION NEUTRON SPECTROMETER [J].
FILCHENKOV, VV ;
KONIN, AD ;
RUDENKO, AI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (03) :504-508
[5]   PULSE HEIGHT-ENERGY RELATIONS FOR ELECTRONS AND ALPHA-PARTICLES IN A LIQUID SCINTILLATOR [J].
FLYNN, KF ;
GLENDENIN, LE ;
STEINBERG, EP ;
WRIGHT, PM .
NUCLEAR INSTRUMENTS & METHODS, 1964, 27 (01) :13-17
[6]   RELATIVE NEUTRON DETECTOR EFFICIENCY AND RESPONSE FUNCTION MEASUREMENTS WITH A CF-252 NEUTRON SOURCE [J].
GUL, K ;
NAQVI, AA ;
ALJUWAIR, HA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02) :470-476
[7]  
KLEIN H, 1979, IEEE T NUCL SCI, V26, P273
[8]   TECHNIQUE FOR DETERMINING BIAS SETTINGS FOR ORGANIC SCINTILLATORS [J].
KNOX, HH ;
MILLER, TG .
NUCLEAR INSTRUMENTS & METHODS, 1972, 101 (03) :519-&
[9]   OPTIMIZING THE ENERGY RESOLUTION OF SCINTILLATION-COUNTERS AT HIGH-ENERGIES [J].
SCHOLERMANN, H ;
KLEIN, H .
NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (01) :25-31
[10]   CALIBRATION OF AN ORGANIC SCINTILLATOR FOR NEUTRON SPECTROMETRY [J].
VERBINSKI, VV ;
BURRUS, WR ;
LOVE, TA ;
ZOBEL, W ;
HILL, NW ;
TEXTOR, R .
NUCLEAR INSTRUMENTS & METHODS, 1968, 65 (01) :8-+