EXTERNAL FIXATION WITH THE ORTHOFIX SYSTEM IN DISLOCATED FRACTURES OF THE LOWER-EXTREMITIES IN CHILDREN

被引:4
作者
SCAVENIUS, M
EBSKOV, LB
SLOTH, C
TORHOLM, C
机构
[1] Department of Orthopaedic Surgery, Copenhagen University Hospital, Gentofte, Hellerup
[2] Department of Radiology, Copenhagen University Hospital, Gentofte, Hellerup
来源
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B | 1993年 / 2卷 / 02期
关键词
EXTERNAL FIXATION; FEMORAL FRACTURES; FRACTURES IN CHILDREN; ORTHOFIX SYSTEM; TIBIAL FRACTURES;
D O I
10.1097/01202412-199302020-00013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Eighteen children with dislocated fractures of the tower extremities were operated on with a dynamic axial unilateral external fixator, the Orthofix system. Telescopic facility allows easy conversion from rigid to dynamic fixation. Seven girls and 11 boys with an average age of 11 3/4 years were treated. The material comprised 10 femoral and nine tibial fractures (one girl had both fracture types). Average follow-up of these children was 19 months. Closed reduction was possible in 11 cases, and eight fractures were treated by open reduction. Physiotherapy for the adjacent joints was started on the second postoperative day. In 14 of the 18 patients, partial weight-bearing crutches was also started at this time. Average hospital stay was 13 days. At the first radiographic indication of periosteal callus, dynamic loading was started. Removal offered as an outpatient procedure, was performed after an average time of 9 weeks. In one case, pin-tract-infection developed, requiring deep soft tissue revision. No pin hole loosening, chronic infection, non-union, and or malalignment occurred. For all patients, we achieved an overall success rate of < 10-degrees angular deviation, < 1.5 cm leg length discrepancy and full range of associated joint movements.
引用
收藏
页码:161 / 169
页数:9
相关论文
共 32 条
[1]  
Asche G., Die Anwendung des Fixateur externe bei kindlichen Frakturen, Zentral Bl Chir, 111, pp. 391-397, (1986)
[2]  
Brooker A.F., The use of external fixation in the treatment of burn patients with fractures, External Fixation: The Current State of Art, pp. 225-237, (1979)
[3]  
Burny F., Traitement par osteotaxis des fractures diaphysaires du tibia. Etude de 115 cas, Acta Orthop Belg, 38, pp. 280-301, (1972)
[4]  
Burny F.L., Elastic external fixation of tibial fractures: Study of 1421 cases, External Fixation: The Current State of Art, pp. 55-72, (1979)
[5]  
Byrd H.S., Cierny J.S., Tebbits J.B., The management of open tibial fractures with associated soft tissue loss
[6]  
external pin fixation with early flap coverage, Plast Reconstr Surg, 67, pp. 73-79, (1981)
[7]  
Court-Brown C., Hughes S.P.F., Experience with the Sukhtian-Hughes external fixation systems, J R Soc Med, 75, pp. 949-957, (1982)
[8]  
De Bastiani G., Renzi Brivio L., Aldegheri R., Benussi F., Requisiti biomeccanici delle fissazione esterna, Giornate Italiane Del Fissatore Esterno, pp. 147-178, (1979)
[9]  
De Bastiani G., Aldegheri R., Renzi Brivio L., The treatment of fractures with a dynamic axial fixator, J Bone Joint Surg [Br], 66, pp. 538-545, (1984)
[10]  
Dehne E., Metz C.W., Deffer P.A., Hall R.M., Non-operative treatment of the fractured tibia by immediate weight bearing, J Trauma, 1, pp. 514-535, (1961)