HIGH-RESOLUTION INTEGRATED GERMANIUM COMPTON POLARIMETER FOR THE GAMMA-RAY ENERGY-RANGE 80 KEV-1 MEV

被引:10
作者
SAREEN, RA
URBAN, W
BARNETT, AR
VARLEY, BJ
机构
[1] Department of Physics and Astronomy, University of Manchester
关键词
D O I
10.1063/1.1145483
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Parameters which govern the choice of a detection system to measure the linear polarization of γ rays at low energies are discussed. An integrated polarimeter is described which is constructed from a single crystal of germanium. It is a compact planar device with the sectors defined electrically, and which gives an energy resolution in the add-back mode of 1 keV at 300 keV. Its performance is demonstrated in a series of calibration measurements using both unpolarized radiation from radioactive sources and polarized γ rays from the 168Er(α,2n)170Yb reaction at E α=25 MeV. Polarization measurements at energies as low as 84 keV have been achieved, where the sensitivity was 0.32±0.09. The sensitivity, efficiency, and energy resolution are reported. Our results indicate that energy resolution should be included in the definition of the figure of merit and we relate the new definition to earlier work. The comparisons show the advantages of the present design in the energy range below 300 keV and its competitiveness up to 1500 keV. © 1995 American Institute of Physics.
引用
收藏
页码:3653 / 3661
页数:9
相关论文
共 25 条
[1]  
AOKI T, 1975, NUCL INSTRUM METHODS, V182, P53
[2]   3 GE(LI) COMPTON POLARIMETER FOR NUCLEAR-REACTION GAMMA-RAYS [J].
ASHIBE, K ;
ADACHI, M ;
TAKETANI, H .
NUCLEAR INSTRUMENTS & METHODS, 1975, 130 (01) :221-225
[3]   SYMMETRICAL 2-CRYSTAL COMPTON POLARIMETER FOR GAMMA-RAYS [J].
BASS, R ;
CHARZEWS.CV ;
BRINKMANN, S ;
HANLE, H .
NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (01) :33-+
[4]   CONSTRUCTION AND USE OF A 3 GE(LI) COMPTON POLARIMETER [J].
BUTLER, PA ;
CARR, PE ;
GADEKEN, LL ;
JAMES, AN ;
NOLAN, PJ ;
SHARPEYS.JF ;
TWIN, PJ ;
VIGGARS, DA .
NUCLEAR INSTRUMENTS & METHODS, 1973, 108 (03) :497-502
[5]  
EWAN GT, 1969, PHYS LETT B, V29, P353
[6]   GAMMA-GAMMA POLARIZED DIRECTIONAL CORRELATIONS SET-UP USING A PLANAR GE(LI) DETECTOR AS POLARIMETER [J].
FILEVICH, A ;
BEHAR, M ;
GARCIABERMUDEZ, G .
NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (03) :521-524
[7]  
GOULDING F, 1972, IEEE T NUCL SCI, V19, P493
[8]   DEVELOPMENT OF A COMPTON POLARIMETER WITH SOLID STATE DETECTORS [J].
HARDY, KA ;
LUMPKIN, A ;
LEE, YK ;
OWEN, GE ;
SHNIDMAN, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (04) :482-&
[9]   ROTATIONAL BANDS IN THE MASS-100 REGION [J].
HOTCHKIS, MAC ;
DURELL, JL ;
FITZGERALD, JB ;
MOWBRAY, AS ;
PHILLIPS, WR ;
AHMAD, I ;
CARPENTER, MP ;
JANSSENS, RVF ;
KHOO, TL ;
MOORE, EF ;
MORSS, LR ;
BENET, P ;
YE, D .
NUCLEAR PHYSICS A, 1991, 530 (01) :111-134
[10]  
ISHII I, 1982, NUCL INSTRUM METHODS, V196, P117