DIAGNOSIS AND QUANTITATIVE-EVALUATION OF SECUNDUM-TYPE ATRIAL SEPTAL-DEFECT BY TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY

被引:40
作者
MORIMOTO, K [1 ]
MATSUZAKI, M [1 ]
TOHMA, Y [1 ]
ONO, S [1 ]
TANAKA, N [1 ]
MICHISHIGE, H [1 ]
MURATA, K [1 ]
ANNO, Y [1 ]
KUSUKAWA, R [1 ]
机构
[1] YAMAGUCHI UNIV,SCH MED,DEPT INTERNAL MED,UBE,YAMAGUCHI 755,JAPAN
关键词
D O I
10.1016/0002-9149(90)90741-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transesophageal echocardiography (horizontal sector scan) was performed in 11 patients with secundum atrial septal defect (ASD). In all 11 patients, transesophageal echocardiography presented the definite visualization of the defect and a clear laminar shunt flow that showed its 2 peaks in late systole and late diastole. We estimated the size of ASD and a shunt volume across the defect by using transesophageal echocardiography. The defect size determined by transesophageal echocardiography was correlated with the surgical measurement (horizontal width, r = 0.92, p < 0.001; vertical length, r = 0.85, p < 0.01). A significant high correlation was shown between the shunt volume measured by transesophageal echocardiography and that by Fick's method (r = 0.87, p < 0.01). There was no significant correlation between the pulmonary to systemic flow volume (ratio) and the mean shunt flow velocity across ASD, although a high linear correlation was observed between the pulmonary to systemic flow ratio and the defect size in horizontal direction (r = 0.82, p < 0.01). Transesophageal echocardiography used for diagnosis and quantitative evaluation of ASD could be performed easily and satisfactorily within 10 minutes. Thus, transesophageal echocardiography is a useful method in evaluation of the defect size and the shunt flow volume of ASD. The mean shunt flow velocity was not a reliable index for estimating the shunt flow volume. The defect size might be a valuable determinant of left-to-right shunt volume in ASD. © 1990.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 21 条
[1]   SUBXIPHOID 2-DIMENSIONAL IMAGING OF THE INTER-ATRIAL SEPTUM IN INFANTS AND NEONATES WITH CONGENITAL HEART-DISEASE [J].
BIERMAN, FZ ;
WILLIAMS, RG .
CIRCULATION, 1979, 60 (01) :80-90
[2]   CROSS-SECTIONAL ECHOCARDIOGRAPHIC EXAMINATION OF INTERATRIAL SEPTUM [J].
DILLON, JC ;
WEYMAN, AE ;
FEIGENBAUM, H ;
EGGLETON, RC ;
JOHNSTON, K .
CIRCULATION, 1977, 55 (01) :115-120
[3]  
FORFAR JC, 1985, BRIT HEART J, V54, P193
[4]  
HANRATH P, 1983, BRIT HEART J, V49, P350
[5]  
HISANAGA K, 1980, CIRCULATION, V62, P34
[6]   NON-INVASIVE EVALUATION OF THE RATIO OF PULMONARY TO SYSTEMIC FLOW IN ATRIAL SEPTAL-DEFECT BY DUPLEX DOPPLER ECHOCARDIOGRAPHY [J].
KITABATAKE, A ;
INOUE, M ;
ASAO, M ;
ITO, H ;
MASUYAMA, T ;
TANOUCHI, J ;
MORITA, T ;
HORI, M ;
YOSHIMA, H ;
OHNISHI, K ;
ABE, H .
CIRCULATION, 1984, 69 (01) :73-79
[7]   ATRIAL PRESSURE-FLOW DYNAMICS IN ATRIAL SEPTAL DEFECTS (SECUNDUM TYPE) [J].
LEVIN, AR ;
SPACH, MS ;
BOINEAU, JP ;
CANENT, RV ;
CAPP, MP ;
JEWETT, PH .
CIRCULATION, 1968, 37 (04) :476-&
[8]   2-DIMENSIONAL ECHOCARDIOGRAPHIC FINDINGS IN ATRIAL SEPTAL-DEFECT [J].
LIEPPE, W ;
SCALLION, R ;
BEHAR, VS ;
KISSLO, JA .
CIRCULATION, 1977, 56 (03) :447-456
[9]   TRANSATRIAL SEPTAL VELOCITY-MEASUREMENT BY DOPPLER ECHOCARDIOGRAPHY IN ATRIAL SEPTAL-DEFECT - CORRELATION WITH QP-QS RATIO [J].
MARX, GR ;
ALLEN, HD ;
GOLDBERG, SJ ;
FLINN, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (09) :1162-1167
[10]   ESOPHAGEAL ECHOCARDIOGRAPHIC LEFT-VENTRICULAR ANTEROLATERAL WALL MOTION IN NORMAL SUBJECTS AND PATIENTS WITH CORONARY-ARTERY DISEASE [J].
MATSUZAKI, M ;
MATSUDA, Y ;
IKEE, Y ;
TAKAHASHI, Y ;
SASAKI, T ;
TOMA, Y ;
ISHIDA, K ;
YOROZU, T ;
KUMADA, T ;
KUSUKAWA, R .
CIRCULATION, 1981, 63 (05) :1085-1092