HARDNESS OF IRRADIATED AND HELIUM IMPLANTED DIN-1.4914 MARTENSITIC STAINLESS-STEEL

被引:6
作者
CHEN, JC
JUNG, P
机构
[1] Association Euratom -KFA, Institut für Festkörperforschung, Forschungszentrum Jülich
关键词
D O I
10.1016/0022-3115(94)90122-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Microhardness of DIN 1.4914 (MANET) martensitic stainless steel, irradiated and helium implanted at room temperature, was measured at temperatures from -180 degrees C to +160 degrees C. Measurements were also performed after annealing at 450 and 650 degrees C and on specimens which were implanted at 600 degrees C and irradiated at 520 degrees C. The results are discussed in terms of the effect of transmutant helium and displacement damage on the ductile to brittle transition temperature.
引用
收藏
页码:559 / 563
页数:5
相关论文
共 52 条
[1]   IRRADIATION HARDENING AND DUCTILITY LOSS OF A LOW-ACTIVATION 9CR-1V FERRITIC STEEL AT LOW-TEMPERATURES [J].
ABE, F ;
NODA, T ;
ARAKI, H ;
NARUI, M ;
KAYANO, H .
JOURNAL OF NUCLEAR MATERIALS, 1989, 166 (03) :265-277
[2]   EFFECT OF SPECIMEN SIZE ON THE DUCTILE BRITTLE TRANSITION BEHAVIOR AND THE FRACTURE SEQUENCE OF 9CR-W STEELS [J].
ABE, F ;
NODA, T ;
ARAKI, H ;
OKADA, M ;
NARUI, M ;
KAYANO, H .
JOURNAL OF NUCLEAR MATERIALS, 1987, 150 (03) :292-301
[3]  
[Anonymous], 1985, EFFECTS RAD MATERIAL
[4]   TENSILE BEHAVIOR AND MICROSTRUCTURE OF THE HELIUM AND HYDROGEN IMPLANTED 12-PERCENT CR-STEEL MANET [J].
BAE, KK ;
EHRLICH, K ;
MOSLANG, A .
JOURNAL OF NUCLEAR MATERIALS, 1992, 191 (pt B) :905-909
[5]  
Baik J.-M., 1986, USE SMALL SCALE SPEC, P92, DOI 10.1520/
[6]  
BASINSKI ZS, 1960, AUST J PHYS, V13, P299
[7]  
CAHOON JR, 1971, METALL TRANS, V2, P1979
[8]  
CHEN J, 1993, KFA JUL2822 REP
[9]  
Corwin W.R., 1986, ASTM STP, V888, P325
[10]   EFFECT OF NICKEL CONTENT OF 9CR-1MOVNB AND 12CR-1MOVW STEELS ON THE AGING AND IRRADIATION RESPONSE OF IMPACT PROPERTIES [J].
CORWIN, WR ;
VITEK, JM ;
KLUEH, RL .
JOURNAL OF NUCLEAR MATERIALS, 1987, 149 (03) :312-320