FILM-COOLING FROM HOLES WITH COMPOUND ANGLE ORIENTATIONS .1. RESULTS DOWNSTREAM OF 2 STAGGERED ROWS OF HOLES WITH 3D SPANWISE SPACING

被引:114
作者
LIGRANI, PM [1 ]
WIGLE, JM [1 ]
CIRIELLO, S [1 ]
JACKSON, SM [1 ]
机构
[1] USN, POSTGRAD SCH, DEPT MECH ENGN, MONTEREY, CA 93943 USA
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 1994年 / 116卷 / 02期
关键词
FORCED CONVECTION; TURBINES;
D O I
10.1115/1.2911406
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental results are presented that describe the development and structure of flow downstream of two staggered rows of film-cooling holes with compound angle orientations. With this configuration, holes are spaced 3d apart in the spanwise direction, inclined at 35 deg with respect to the test surface when projected into the streamwise/normal plane, and inclined at 30 deg with respect to the test surface when projected into the spanwise/normal plane. Results are presented for an injectant to free-stream density ratio near 1.0, and injection blowing ratios from 0.5 to 1.50. Comparisons are made with measurements from two other configurations to determine: (1) the effects of hole angle orientation for constant spanwise hole spacing, and (2) the effects of spanwise hole spacing when the hole angle orientation is maintained constant. Results from the first comparison show that the compound angle injection configuration provides significantly improved film-cooling protection compared to a simple angle configuration for the same spanwise hole spacing, normalized streamwise location x/d, and blowing ratio m, for x/d < 60. At x/d > 60, spanwise-averaged adiabatic effectiveness data downstream of the two configurations generally cover about the same range. Results from the second comparison show that spanwise-averaged effectiveness values are 25 to 40 percent higher when 3d span wise hole spacing is employed compared to 3.9d span wise hole spacing for the same m and x/d, for x/d < 40. At x/d > 40, differences between the two configurations range from 12 to 30 percent. Results from all configurations studied show that spanwise-averaged iso-energetic Stanton number ratios cover approximately the same range of values and show roughly the same trends, ranging between 1.0 and 1.25. In particular, St(f)/St(o) values increase with m at each x/d, and show little variation with x/d for each value of m tested.
引用
收藏
页码:341 / 352
页数:12
相关论文
共 17 条
[1]  
BISHOP DT, 1990, THESIS NAVAL POSTGRA
[2]   THE INFLUENCE OF A LAMINAR BOUNDARY-LAYER AND LAMINAR INJECTION ON FILM COOLING PERFORMANCE [J].
GOLDSTEIN, RJ ;
YOSHIDA, T .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (02) :355-362
[3]  
GOLDSTEIN RJ, 1970, ISRAEL J TECHNOL, V8, P145
[4]  
JABBARI MY, 1978, ASME, V100, P303
[5]  
Kays W.M., 1993, CONVECTIVE HEAT MASS, V3rd edn
[6]  
KIM HK, 1978, HMT28 STANF U DEP ME
[7]  
Kline S.J., 1953, J I ENG, V1, P3, DOI DOI 10.1016/J.CHAOS.2005.11.046
[8]   ADIABATIC FILM COOLING EFFECTIVENESS FROM HEAT-TRANSFER MEASUREMENTS IN COMPRESSIBLE, VARIABLE-PROPERTY FLOW [J].
LIGRANI, PM ;
CAMCI, C .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1985, 107 (02) :313-320
[9]   FILM-COOLING FROM HOLES WITH COMPOUND ANGLE ORIENTATIONS .2. RESULTS DOWNSTREAM OF A SINGLE ROW OF HOLES WITH 6D SPANWISE SPACING [J].
LIGRANI, PM ;
WIGLE, JM ;
JACKSON, SW .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1994, 116 (02) :353-362
[10]   HEAT-TRANSFER, ADIABATIC EFFECTIVENESS, AND INJECTANT DISTRIBUTIONS DOWNSTREAM OF A SINGLE ROW AND 2 STAGGERED ROWS OF COMPOUND ANGLE FILM-COOLING HOLES [J].
LIGRANI, PM ;
CIRIELLO, S ;
BISHOP, DT .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1992, 114 (04) :687-700