Detection of subtle beat-to-beat variations in the morphology of the ECG is complicated by the effects of alignment errors and respiration. A method of directly estimating the alignment error (trigger jitter) from an ECG is derived by relating the variance to the squared slope of the averaged QRS complex. Results based on recordings obtained from 12 normal subjects and alignment performed by the cross-correlation method showed that the alignment errors were dependent upon the choice of the alignment channel, with the best distribution of the errors occurring when alignment was based on the vector magnitude of the three orthogonal leads. The estimated average alignment errors ranged from 0.33-0.42 ms, which were near the optimal value o f 0.29 ms based on the sampling rate of 1000 samples/s. It was shown that the effects of respiration could be reduced by normalizing the amplitude of the QRS complexes. It was also estimated that a significant proportion of the variation (0.54-0.67) in the normalized ECG's could be attributed to alignment errors and noise.
引用
收藏
页码:736 / 741
页数:6
相关论文
共 17 条
[1]   RESPIRATION AND THE ECG - A STUDY USING BODY-SURFACE POTENTIAL MAPS [J].
AMOORE, JN ;
RUDY, Y ;
LIEBMAN, J .
JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (03) :263-271
[2]   BEAT TO BEAT VARIABILITY IN CARDIOVASCULAR VARIABLES - NOISE OR MUSIC [J].
APPEL, ML ;
BERGER, RD ;
SAUL, JP ;
SMITH, JM ;
COHEN, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1139-1148
[3]   BEAT-TO-BEAT ELECTROCARDIOGRAPHIC MORPHOLOGY VARIATION IN HEALED MYOCARDIAL-INFARCTION [J].
BENHAIM, SA ;
BECKER, B ;
EDOUTE, Y ;
KOCHANOVSKI, M ;
AZARIA, O ;
KAPLINSKY, E ;
PALTI, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (08) :725-728
[4]   CRITERIA FOR OPTIMAL AVERAGING OF CARDIAC SIGNALS [J].
CRAELIUS, W ;
RESTIVO, M ;
ASSADI, MA ;
ELSHERIF, N .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (10) :957-966
[5]   ON THE DIRECTION AND MANIFEST SIZE OF THE VARIATIONS OF POTENTIAL IN THE HUMAN HEART AND ON THE INFLUENCE OF THE POSITION OF THE HEART ON THE FORM OF THE ELECTROCARDIOGRAM [J].
EINTHOVEN, W ;
FAHR, G ;
DEWAART, A .
AMERICAN HEART JOURNAL, 1950, 40 (02) :163-211
[6]   RELATION OF ELECTROCARDIOGRAPHIC-R-WAVE AMPLITUDE TO CHANGES IN LEFT-VENTRICULAR CHAMBER SIZE AND POSITION IN NORMAL SUBJECTS [J].
FELDMAN, T ;
BOROW, KM ;
NEUMANN, A ;
LANG, RM ;
CHILDERS, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (09) :1168-1174
[7]   ALIGNMENT METHODS FOR AVERAGING OF HIGH-RESOLUTION CARDIAC SIGNALS - A COMPARATIVE-STUDY OF PERFORMANCE [J].
JANE, R ;
RIX, H ;
CAMINAL, P ;
LAGUNA, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (06) :571-579
[8]   SPATIAL DOMAIN ANALYSIS OF LATE VENTRICULAR POTENTIALS - INTRAOPERATIVE AND THORACIC CORRELATIONS [J].
LACROIX, D ;
SAVARD, P ;
SHENASA, M ;
KALTENBRUNNER, W ;
CARDINAL, R ;
PAGE, P ;
JOLY, D ;
DEROME, D ;
NADEAU, R .
CIRCULATION RESEARCH, 1990, 66 (01) :55-68
[9]   THE EFFECT OF RESPIRATION-INDUCED HEART MOVEMENTS ON THE ECG [J].
PALLASARENY, R ;
COLOMINASBALAGUE, J ;
ROSELL, FJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (06) :585-590
[10]   COHERENT AVERAGING TECHNIQUE - A TUTORIAL REVIEW .2. TRIGGER JITTER, OVERLAPPING RESPONSES AND NONPERIODIC STIMULATION [J].
ROMPELMAN, O ;
ROS, HH .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (01) :30-35