ERRORS IN MEASUREMENTS OF STROKE VOLUME FOR INVASIVE AND ECHO-DOPPLER EVALUATIONS OF VALVULAR REGURGITANT FRACTIONS - CLINICAL-EVALUATION AND COMPUTER-SIMULATION

被引:15
作者
ILICETO, S
DAMBROSIO, G
AMICO, A
TOTA, F
PICCINNI, G
MARANGELLI, V
RIZZON, P
机构
[1] Division of Cardiology, University of Bari, Bari
关键词
Echo-Doppler; Regurgitant fraction;
D O I
10.1093/oxfordjournals.eurheartj.a059710
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare cardiac catheterization (CATH) with 2D echo-Doppler (ED) in clinically evaluating the stroke volumes (SV) needed to calculate aortic and mitral regurgitant fractions (aortic and mitral SV for the ED method, thermodilution and angiographic SVfor the CA TH). As there is no 'gold standard' for this kind of measurement, only subjects without valvular regurgitation were considered. In these subjects, though the two SV measurements needed to calculate the regurgitant volume should have been identical, there was, in fact a difference due to the systematic and random errors of the methods. We calculated the mean value and the standard deviation of this difference in a series of patients without valvular regurgitation in order to obtain an estimate of both systematic and random errors.In 20 patients studied by ED a difference of 11.9±16.7 ml was found. In 36 patients studied by cardiac catheterization the difference was 19.6 ± 20.1 ml. A significant systematic error was found for both ED and the invasive method; The transmitral SV tended to be larger than the aortic and the angiographic SV larger than that obtained by thermodilution.To try to determine the extent to which the random errors could be attributed to the reproducibility of the measurements, we carried out computer simulations. The SVs of 50 000 hypothetical patients were randomly generated and then attributed a random error calculated on the basis of the variability of the CA TH (thermodilution 4%, angiography 10%) and the ED measurements (aortic annulus 6%, mitral annulus 18%, mitral time velocity integral 10%, aortic time velocity integral 8%). We obtained a simulated difference of 0.92 ± 14.7 for ED and of 0.12 ±8.4 for CATH. Mean values of simulated differences are obviously close to zero, because of the absence of systematic error. The simulated and observed random errors for the ED method were not statistically different, while a significant difference was found between the real and the simulated value for the CA TH. This can be explained by taking other sources of error into consideration (differences between the angiographic and thermodilution techniques, invasive techniques interfering with haemodynamic parameters).It can be concluded that the determination of the S Vs has too high a margin of error in both methods for it to be used in clinical practice for evaluating the RF. For the ED, this error is mainly due to inaccuracy in the anatomic and flow velocity measurements whereas, with CA TH, it is partly due to measurement reproducibility and partly to the method itself. © 1990 The European Society of Cardiology.
引用
收藏
页码:355 / 360
页数:6
相关论文
共 20 条
  • [1] ASCHA KJ, 1985, CIRCULATION, V72, P377
  • [2] ANGIOCARDIOGRAPHIC EVALUATION OF VALVULAR INSUFFICIENCY
    BARON, MG
    [J]. CIRCULATION, 1971, 43 (04) : 599 - &
  • [3] QUANTITATION OF MITRAL REGURGITATION BY DOPPLER ECHOCARDIOGRAPHY
    BLUMLEIN, S
    BOUCHARD, A
    SCHILLER, NB
    DAE, M
    BYRD, BF
    PORTS, T
    BOTVINICK, EH
    [J]. CIRCULATION, 1986, 74 (02) : 306 - 314
  • [4] BOWMAN LK, 1986, CIRCULATION, V74, P217
  • [5] LIMITATIONS OF QUALITATIVE ANGIOGRAPHIC GRADING IN AORTIC OR MITRAL REGURGITATION
    CROFT, CH
    LIPSCOMB, K
    MATHIS, K
    FIRTH, BG
    NICOD, P
    TILTON, G
    WINNIFORD, MD
    HILLIS, LD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (11) : 1593 - 1598
  • [6] SUPERIORITY OF TWO-DIMENSIONAL MEASUREMENT OF AORTIC VESSEL DIAMETER IN DOPPLER ECHOCARDIOGRAPHIC ESTIMATES OF LEFT-VENTRICULAR STROKE VOLUME
    GARDIN, JM
    TOBIS, JM
    DABESTANI, A
    SMITH, C
    ELKAYAM, U
    CASTLEMAN, E
    WHITE, D
    ALLFIE, A
    HENRY, WL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (01) : 66 - 74
  • [7] EVALUATION OF PULMONARY AND SYSTEMIC BLOOD-FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY USING FAST FOURIER-TRANSFORM SPECTRAL-ANALYSIS
    GOLDBERG, SJ
    SAHN, DJ
    ALLEN, HD
    VALDESCRUZ, LM
    HOENECKE, H
    CARNAHAN, Y
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) : 1394 - 1400
  • [8] COLOR DOPPLER ASSESSMENT OF MITRAL REGURGITATION WITH ORTHOGONAL PLANES
    HELMCKE, F
    NANDA, NC
    HSIUNG, MC
    SOTO, B
    ADEY, CK
    GOYAL, RG
    GATEWOOD, RP
    [J]. CIRCULATION, 1987, 75 (01) : 175 - 183
  • [9] HUNTSMAN LL, 1983, CIRCULATION, V67, P539
  • [10] KENNEDY JW, 1978, AM J CARDIOL, V41, P726