HEPATIC IRON OVERLOAD - QUANTITATIVE MR IMAGING

被引:103
作者
GOMORI, JM
HOREV, G
TAMARY, H
ZANDBACK, J
KORNREICH, L
ZAIZOV, R
FREUD, E
KRIEF, O
BENMEIER, J
ROTEM, H
KUSPET, M
ROSEN, P
RACHMILEWITZ, EA
LOEWENTHAL, E
GORODETSKY, R
机构
[1] ELSCINT LTD,HAIFA,ISRAEL
[2] HADASSAH UNIV HOSP,DEPT ONCOL,IL-91120 JERUSALEM,ISRAEL
[3] HADASSAH UNIV HOSP,DEPT HEMATOL,IL-91120 JERUSALEM,ISRAEL
[4] BEILINSON MED CTR,DEPT PEDIAT HEMATOL ONCOL,IL-49100 PETAH TIQWA,ISRAEL
[5] BEILINSON MED CTR,DEPT SURG,IL-49100 PETAH TIQWA,ISRAEL
[6] BEILINSON MED CTR,DEPT PATHOL,IL-49100 PETAH TIQWA,ISRAEL
[7] BEILINSON MED CTR,DEPT PEDIAT RADIOL,IL-49100 PETAH TIQWA,ISRAEL
关键词
ANEMIA; LIVER; DISEASES; IRON CONTENT; MR STUDIES; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES;
D O I
10.1148/radiology.179.2.2014276
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iron deposits demonstrate characteristically shortened T2 relaxation times. Several previously published studies reported poor correlation between the in vivo hepatic 1/T2 measurements made by means of midfield magnetic resonance (MR) units and the hepatic iron content of iron-overloaded patients. In this study, the authors assessed the use of in vivo 1/T2 measurements obtained by means of MR imaging at 0.5 T using short echo times (13.4 and 30 msec) and single-echo sequences as well as computed tomographic (CT) attenuation as a measure of liver iron concentration in 10 severely iron-overloaded patients with beta-thalassemia major. The iron concentrations in surgical wedge biopsy samples of the liver, which varied between 3 and 9 mg/g of wet weight (normal, less-than-or-equal-to 0.5 mg/g), correlated well (r = .93, P less-than-or-equal-to .0001) with the preoperative in vivo hepatic 1/T2 measurements. The CT attenuation did not correlate with liver iron concentration. Quantitative MR imaging is a readily available noninvasive method for the assessment of hepatic iron concentration in iron-overloaded patients, reducing the need for needle biopsies of the liver.
引用
收藏
页码:367 / 369
页数:3
相关论文
共 26 条
[1]   MAGNETIC-RESONANCE IMAGING OF TRANSFUSIONAL HEMOSIDEROSIS COMPLICATING THALASSEMIA MAJOR [J].
BRASCH, RC ;
WESBEY, GE ;
GOODING, CA ;
KOERPER, MA .
RADIOLOGY, 1984, 150 (03) :767-771
[2]   MAGNETIC-SUSCEPTIBILITY MEASUREMENT OF HUMAN IRON STORES [J].
BRITTENHAM, GM ;
FARRELL, DE ;
HARRIS, JW ;
FELDMAN, ES ;
DANISH, EH ;
MUIR, WA ;
TRIPP, JH ;
BELLON, EM .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (27) :1671-1675
[3]   HEPATIC IRON OVERLOAD - DIAGNOSIS AND QUANTIFICATION BY NONINVASIVE IMAGING [J].
CHEZMAR, JL ;
NELSON, RC ;
MALKO, JA ;
BERNARDINO, ME .
GASTROINTESTINAL RADIOLOGY, 1990, 15 (01) :27-31
[4]  
EDELMAN RR, 1986, AM J NEURORADIOL, V7, P751
[5]  
Gomori J M, 1988, Radiographics, V8, P427
[6]   MR RELAXATION-TIMES AND IRON CONTENT OF THALASSEMIC SPLEENS - AN INVITRO STUDY [J].
GOMORI, JM ;
GROSSMAN, RI ;
DROTT, HR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :567-569
[7]   INTRACRANIAL HEMATOMAS - IMAGING BY HIGH-FIELD MR [J].
GOMORI, JM ;
GROSSMAN, RI ;
GOLDBERG, HI ;
ZIMMERMAN, RA ;
BILANIUK, LT .
RADIOLOGY, 1985, 157 (01) :87-93
[8]  
GORODETSKY R, 1985, J LAB CLIN MED, V105, P44
[9]   MR EVALUATION OF LIVER IRON OVERLOAD [J].
HERNANDEZ, RJ ;
SARNAIK, SA ;
LANDE, I ;
AISEN, AM ;
GLAZER, GM ;
CHENEVERT, T ;
MARTEL, W .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (01) :91-94
[10]  
HOUANG MTW, 1979, LANCET, V1, P1322