OSTEOLYSIS AFTER TOTAL KNEE ARTHROPLASTY WITHOUT CEMENT

被引:285
作者
PETERS, PC [1 ]
ENGH, GA [1 ]
DWYER, KA [1 ]
VINH, TN [1 ]
机构
[1] ANDERSON ORTHOPAED RES INST,ARLINGTON,VA 22206
关键词
D O I
10.2106/00004623-199274060-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The prevalence and characteristics of osteolysis were studied after 174 consecutive total knee arthroplasties, performed without cement; 16 per cent (twenty-seven) of the implants (in twenty-six patients) were identified as being associated with osteolysis. The diagnosis was made an average of thirty-rive months after the operation. Fifteen (56 per cent) of the twenty-seven prostheses were revised after an average of forty-five months in situ. The remaining twelve implants were still in situ five years or more postoperatively. In the patients who were managed with revision, six implants were judged to be stable radiographically and intraoperatively. The remaining nine implants were loose. The average age of the patients who had osteolysis was sixty-three years, and the average weight was seventy-six kilograms (168 pounds). Eighteen of the twenty-six patients who had osteolysis were women. The medial aspect of the tibial metaphysis was the most common site for resorption of bone (twenty-four knees). Sequential radiographs demonstrated progressive extension of the osteolytic process around the tibial base-plate of the prosthesis and distally into the tibial metaphysis along the screw-bone interface in all patients. Histological evaluation of tissue obtained at the revision procedures revealed sheets of histiocytes and occasional giant cells. Intracellular particulate polyethylene and metal were found; most particles were less than one micrometer in size, although particles as large as three micrometers were identified. Mechanical failure of the thin, modular, polyethylene tibial insert; excessive abrasion of the prominent polyethylene tibial eminence, with secondary wear and impingement of the pin on the femoral component; and failure of the metal-backed patellar component all contributed to the extensive amount of polyethylene and the variable amount of metal debris that were generated. Corrosion between the angulated titanium screws and the cobalt-chromium base-plate also contributed particulate metal to the osteolytic process locally. This study demonstrated that osteolysis occurs in association with cementless total knee replacement.
引用
收藏
页码:864 / 876
页数:13
相关论文
共 45 条
  • [1] Bartel D L, 1983, Hip, P229
  • [2] THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT
    BARTEL, DL
    BICKNELL, VL
    WRIGHT, TM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) : 1041 - 1051
  • [3] A STUDY OF IMPLANT FAILURE IN THE WAGNER RESURFACING ARTHROPLASTY
    BELL, RS
    SCHATZKER, J
    FORNASIER, VL
    GOODMAN, SB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (08) : 1165 - 1175
  • [4] METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT
    BLACK, J
    SHERK, H
    BONINI, J
    ROSTOKER, WR
    SCHAJOWICZ, F
    GALANTE, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) : 126 - 130
  • [5] OSTEOLYTIC CHANGES IN THE UPPER FEMORAL-SHAFT FOLLOWING POROUS-COATED HIP-REPLACEMENT
    BROWN, IW
    RING, PA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02): : 218 - 221
  • [6] CAMPBELL P, 1990, OCT S BIOC PART IMPL
  • [7] LOCALIZED BONE-RESORPTION IN THE FEMUR IN MECHANICAL FAILURE OF CEMENTED TOTAL HIP ARTHROPLASTIES
    CARLSSON, AS
    GENTZ, CF
    LINDER, L
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (03): : 396 - 402
  • [8] COLLIER JP, 1990, CLIN ORTHOP RELAT R, V261, P107
  • [9] Cook SD, 1991, CLIN ORTHOP RELAT R, V264, P209
  • [10] DANNENMAIER WC, 1985, CLIN ORTHOP RELAT R, V198, P224