IMPEDANCE ELECTRODES POSITIONED ON PROXIMAL PORTIONS OF LIMBS QUANTIFY FLUID COMPARTMENTS IN DOGS

被引:25
作者
SCHELTINGA, MR
HELTON, WS
ROUNDS, J
JACOBS, DO
WILMORE, DW
机构
[1] Dept. of Surgery, Brigham and Women's Hospital, Boston, MA 02115, Francis St.
关键词
BODY COMPOSITION; PHYSIOLOGICAL MONITORING; BIOELECTRICAL IMPEDANCE ANALYSIS;
D O I
10.1152/jappl.1991.70.5.2039
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Body resistance and reactance to the conduction of an alternating electrical current were measured using electrodes attached to distal and proximal portions of limbs in anesthetized dogs. Body impedance was calculated from these measurements obtained at 30-min time intervals during a control period and after intravenous administration of 0.9% saline. Extracellular (ECW) and total body water (TBW) were determined by bromide and heavy water dilution techniques, respectively. Baseline impedance obtained from proximal electrodes was related to ECW (r = 0.95, P < 0.001) and TBW (r = 0.80, P < 0.02). After saline infusion, proximal electrodes detected a significant fall in impedance (P < 0.001), whereas distal electrodes did not (P = 0.06). Furthermore, ECW and TBW could be estimated from the drop of proximal impedance after this bolus infusion (r = 0.82, P < 0.02, and r = 0.86, P < 0.01, respectively), but not from distal impedance measurements. Proximally placed impedance electrodes are superior to traditionally used distal electrodes for assessment of body fluid changes in the dog.
引用
收藏
页码:2039 / 2044
页数:6
相关论文
共 25 条
[1]   PRINCIPLES OF THE IMPEDANCE TECHNIQUE [J].
BAKER, LE .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1989, 8 (01) :11-15
[2]   BIOELECTRIC IMPEDANCE PHASE-ANGLE AND BODY-COMPOSITION [J].
BAUMGARTNER, RN ;
CHUMLEA, WC ;
ROCHE, AF .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (01) :16-23
[3]  
Bell E F, 1984, Pediatr Res, V18, P392, DOI 10.1203/00006450-198404000-00021
[4]  
DEMSTER WT, 1967, AM J ANAT, V120, P33
[5]   CORRELATION OF WHOLE-BODY IMPEDANCE WITH TOTAL BODY WATER VOLUME [J].
HOFFER, EC ;
MEADOR, CK ;
SIMPSON, DC .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (04) :531-&
[7]  
KHALED MA, 1987, AM J CLIN NUTR, V45, P1
[8]   ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
KUSHNER, RF ;
SCHOELLER, DA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03) :417-424
[9]  
LUKASKI HC, 1988, AVIAT SPACE ENVIR MD, V59, P1163
[10]   ASSESSMENT OF FAT-FREE MASS USING BIOELECTRICAL IMPEDANCE MEASUREMENTS OF THE HUMAN-BODY [J].
LUKASKI, HC ;
JOHNSON, PE ;
BOLONCHUK, WW ;
LYKKEN, GI .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (04) :810-817