SKIN DOSE MEASUREMENTS FOR HEAD AND NECK RADIOTHERAPY

被引:15
作者
FIORINO, C
CATTANEO, GM
DELVECCHIO, A
LONGOBARDI, B
SIGNOROTTO, P
CALANDRINO, R
FOSSATI, V
VOLTERRANI, F
机构
[1] SCI INST H SAN RAFFAELE,DEPT RADIAT ONCOL,I-20132 MILAN,ITALY
[2] INST RADIOL SCI,MILAN,ITALY
关键词
SKIN DOSE; BUILDUP; DOSIMETRY; IMMOBILIZATION; HEAD AND NECK TUMORS;
D O I
10.1118/1.596758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of immobilization plastic masks in head and neck radiotherapy can partially eliminate skin benefits derived from the utilization of megavoltage photon beams. Filters and blocks between the patient and the accelerator can further increase the skin dose value. In this study, the increase in surface dose due to 2 and 3.2 mm of plastic material utilized for patient immobilization was measured. Then, the effect of blocking trays, wedges, and blocks on skin dose in typical conditions for head and neck irradiation was evaluated. The measurements were obtained with a NE2534 chamber (Markus type) on a perspex phantom for 6 MeV x-rays from an accelerator.
引用
收藏
页码:1263 / 1266
页数:4
相关论文
共 12 条
[1]   STOPPING POWER DATA FOR HIGH-ENERGY PHOTON BEAMS [J].
ANDREO, P ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (08) :839-858
[2]   VALIDITY OF TRANSITION-ZONE DOSIMETRY AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS [J].
DAS, IJ ;
KASE, KR ;
MEIGOONI, AS ;
KHAN, FM ;
WERNER, BL .
MEDICAL PHYSICS, 1990, 17 (01) :10-16
[3]   THE USE OF THERMAL PLASTICS FOR IMMOBILIZATION OF PATIENTS DURING RADIOTHERAPY [J].
GERBER, RL ;
MARKS, JE ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (08) :1461-1462
[4]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[5]   THE POLARITY EFFECT FOR COMMERCIALLY AVAILABLE PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1987, 14 (02) :210-215
[6]   DETERMINATION OF BUILDUP REGION OVER-RESPONSE CORRECTIONS FOR A MARKUS-TYPE CHAMBER [J].
MELLENBERG, DE .
MEDICAL PHYSICS, 1990, 17 (06) :1041-1044
[7]   FLUENCE PERTURBATION IN PHOTON BEAMS UNDER NONEQUILIBRIUM CONDITIONS [J].
NILSSON, B ;
MONTELIUS, A .
MEDICAL PHYSICS, 1986, 13 (02) :191-195
[8]   BUILDUP SURFACE DOSE AND EXIT DOSE MEASUREMENTS FOR A 6-MV LINEAR-ACCELERATOR [J].
PURDY, JA .
MEDICAL PHYSICS, 1986, 13 (02) :259-262
[9]  
Purdy JR, 1990, ADV RAD ONCOLOGY PHY
[10]   BUILDUP REGION AND SKIN-DOSE MEASUREMENTS FOR THE THERAC-6 LINEAR-ACCELERATOR FOR RADIATION-THERAPY [J].
TANNOUS, NBJ ;
GAGNON, WF ;
ALMOND, PR .
MEDICAL PHYSICS, 1981, 8 (03) :378-381