FABRICATION OF ELECTRODE ARRAYS IN THE QUARTER MICRON REGIME FOR BIOTECHNOLOGICAL APPLICATIONS

被引:20
作者
REIMER, K [1 ]
KOHLER, C [1 ]
LISEC, T [1 ]
SCHNAKENBERG, U [1 ]
FUHR, G [1 ]
HINTSCHE, R [1 ]
WAGNER, B [1 ]
机构
[1] HUMBOLDT UNIV BERLIN,FB BIOL,D-10115 BERLIN,GERMANY
关键词
ELECTRODE ARRAYS; BIOTECHNOLOGY;
D O I
10.1016/0924-4247(94)00863-D
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the field of biotechnological microsystems there is a strong demand for the fabrication of ultraminiaturised electrodes. Examples are highly sensitive biosensors or electric field induced handling of biological cells and macromolecules. New effects and thus new fields of applications appear when the electrode dimensions reach the 100 nm scale. This paper presents two alternative technologies for the fabrication of biocompatible microelectrodes: a platinum lift-off process and a gold electroplating process. The lithography was performed with a Leica EBPG 4 HR electron-beam writer at 50 kV acceleration voltage. An electrode size dependent exposure dose was calculated from the effect of backscattered electrons (proximity effect). Evaporated platinum lines with 200 nm spaces could be realized. The electrodes are embedded in SiO2 yielding a nearly planar surface. In the second case 140 nm gold lines with 60 nm spaces were electroplated using a sulphitic plating solution.
引用
收藏
页码:66 / 70
页数:5
相关论文
共 11 条
[1]   PARTICLE MICROMANIPULATOR CONSISTING OF 2 ORTHOGONAL CHANNELS WITH TRAVELING-WAVE ELECTRODE STRUCTURES [J].
FUHR, G ;
FIEDLER, S ;
MULLER, T ;
SCHNELLE, T ;
GLASSER, H ;
LISEC, T ;
WAGNER, B .
SENSORS AND ACTUATORS A-PHYSICAL, 1994, 41 (1-3) :230-239
[2]  
FUHR G, 1995, SENSOR ACTUAT B-CHEM, V26, P468
[3]  
HAGEDORN R, 1993, EELECTROPHORESIS, V13, P49
[4]  
HINTSCHE R, 1992, 7TH P INT C SOL STAT, P476
[5]   APPLICATION OF E-BEAM NANOLITHOGRAPHY FOR ABSORBER STRUCTURING OF HIGH-RESOLUTION X-RAY MASKS [J].
KOHLER, C ;
BRUNGER, W ;
EHRLICH, C ;
HUBER, H ;
REIMER, K .
MICROELECTRONIC ENGINEERING, 1993, 21 (1-4) :159-164
[6]  
Lochel B., 1990, Microelectronic Engineering, V11, P279, DOI 10.1016/0167-9317(90)90115-A
[7]   A TRAVELING-WAVE MICROPUMP FOR AQUEOUS-SOLUTIONS - COMPARISON OF 1-G AND MU-G RESULTS [J].
MULLER, T ;
ARNOLD, WM ;
SCHNELLE, T ;
HAGEDORN, R ;
FUHR, G ;
ZIMMERMANN, U .
ELECTROPHORESIS, 1993, 14 (08) :764-772
[8]   ELECTROCHEMICAL-BEHAVIOR OF REVERSIBLE REDOX SPECIES AT INTERDIGITATED ARRAY ELECTRODES WITH DIFFERENT GEOMETRIES - CONSIDERATION OF REDOX CYCLING AND COLLECTION EFFICIENCY [J].
NIWA, O ;
MORITA, M ;
TABEI, H .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :447-452
[9]  
Paeschke M., 1995, SENSOR ACTUAT B-CHEM, V26-27, P394
[10]  
SCHELLER F, 1992, BIOSENSORS, P184