A 37 CHANNEL DC SQUID MAGNETOMETER SYSTEM

被引:48
作者
KOCH, H
CANTOR, R
DRUNG, D
ERNE, SN
MATTHIES, KP
PETERS, M
RYHANEN, T
SCHEER, HJ
HAHLBOHM, HD
机构
[1] Physikalisch- Technische Bundesanstalt, Institut Berlin, D-1000, Berlin
[2] Helsinki University of Technology, 02150, Espoo
基金
芬兰科学院;
关键词
Biomagnetism - DC SQUID - Gradiometers;
D O I
10.1109/20.133788
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 37 channel dc SQUID magnetometer system has been built for biomagnetic studies. The SQUID loop of each magnetometer serves as the active sensing element, thereby eliminating the need for flux coupling circuits. The magnetometers are located congruent-to 3 cm above the outer dewar bottom. The SQUIDs are directly coupled to a highly simplified read-out electronics using only 5 wires per channel; no helium temperature impedance matching circuits are required. Each channel can be independently inserted into or removed from the dewar. Using a novel compensation technique the system white and 1 Hz flux density noise values are typically 5 fT/square-root Hz and 10 fT/square-root Hz, respectively, including the noise contribution of the in-house fabricated dewar (about 2 fT/square-root Hz at 100 Hz) and the magnetically shielded room (about 1 fT/square-root Hz at 100 Hz). In addition it is shown that due to the large dynamic range and high slew rate of the sensors it is possible to electronically form a gradiometric configuration that can be advantageously exploited in order to improve the signal-to-noise ratio.
引用
收藏
页码:2793 / 2796
页数:4
相关论文
共 20 条
[1]   PLASMA NITRIDATION PROCESS FOR THE FABRICATION OF ALL-REFRACTORY JOSEPHSON-JUNCTIONS [J].
CANTOR, R ;
DRUNG, D ;
PETERS, M ;
KOCH, H .
JOURNAL OF APPLIED PHYSICS, 1990, 67 (06) :3038-3042
[2]   INTEGRATED DC-SQUID MAGNETOMETER WITH SIMPLIFIED READ-OUT [J].
CANTOR, R ;
DRUNG, D ;
PETERS, M ;
SCHEER, HJ ;
KOCH, H .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1990, 3 (02) :108-112
[3]   DESIGN AND OPTIMIZATION OF DC SQUIDS FABRICATED USING A SIMPLIFIED 4-LEVEL PROCESS [J].
CANTOR, R ;
RYHANEN, T ;
DRUNG, D ;
KOCH, H ;
SEPPA, H .
IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) :2927-2931
[4]  
CANTOR R, 1989, 1989 INT SUP EL C IS, P63
[5]   MEASURED PERFORMANCE PARAMETERS OF GRADIOMETERS WITH DIGITAL OUTPUT [J].
DRUNG, D ;
CROCOLL, E ;
HERWIG, R ;
NEUHAUS, M ;
JUTZI, W .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (02) :1034-1037
[6]   LOW-NOISE HIGH-SPEED DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER WITH SIMPLIFIED FEEDBACK ELECTRONICS [J].
DRUNG, D ;
CANTOR, R ;
PETERS, M ;
SCHEER, HJ ;
KOCH, H .
APPLIED PHYSICS LETTERS, 1990, 57 (04) :406-408
[7]  
DRUNG D, 1991, IEEE T MAGNETICS, V27
[8]   EFFECT OF DAMPING RESISTANCE ON VOLTAGE VERSUS FLUX RELATION OF A DC SQUID WITH LARGE INDUCTANCE AND CRITICAL CURRENT [J].
ENPUKU, K ;
SUEOKA, K ;
YOSHIDA, K ;
IRIE, F .
JOURNAL OF APPLIED PHYSICS, 1985, 57 (05) :1691-1697
[9]  
ERNE SN, 1981, BIOMAGNETISM, P79
[10]   A NOVEL MODULATION TECHNIQUE FOR 1/F NOISE-REDUCTION IN DC SQUIDS [J].
FOGLIETTI, V ;
GALLAGHER, WJ ;
KOCH, RH .
IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) :1150-1153