COMPARISON OF RB-82 POSITRON EMISSION TOMOGRAPHY AND TL-201 SPECT IMAGING FOR DETECTION OF CORONARY-ARTERY DISEASE

被引:176
作者
STEWART, RE [1 ]
SCHWAIGER, M [1 ]
MOLINA, E [1 ]
POPMA, J [1 ]
GACIOCH, GM [1 ]
KALUS, M [1 ]
SQUICCIARINI, S [1 ]
ALAOUAR, ZR [1 ]
SCHORK, A [1 ]
KUHL, DE [1 ]
机构
[1] UNIV MICHIGAN, MED CTR,DEPT INTERNAL MED,DIV NUCL MED, 1500 E MED CTR DR, ANN ARBOR, MI 48109 USA
关键词
D O I
10.1016/0002-9149(91)90456-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The diagnostic performance of rubidium-82 (Rb-82) positron emission tomography (PET) and thallium-201 (TI-201) single-photon emission-computed tomography (SPECT) for detecting coronary artery disease was investigated in 81 patients (52 men, 29 women). PET studies using 60 mCi of Rb-82 were performed at baseline and after intravenous infusion of 0.56 mg/kg dipyridamole in conjunction with handgrip stress. TI-201 SPECT was performed after dipyridamole-handgrip stress and, in a subset of patients, after treadmill exercise. Sensitivity, specificity and overall diagnostic accuracy were assessed using both visually and quantitatively interpreted coronary angiograms. The overall sensitivity, specificity and accuracy of PET for detection of coronary artery disease (> 50% diameter stenosis) were 84, 88 and 85%, respectively. In comparison, the performance of SPECT revealed a sensitivity of 84%, specificity of 53% (p < 0.05 vs PET) and accuracy of 79%. Similar results were obtained using either visual or quantitative angiographic criteria for severity of coronary artery disease. In 43 patients without prior myocardial infarction, the sensitivity for detection of disease was 71 and 73%, respectively, similar for both PET and SPECT. There was no significant difference in diagnostic performance between imaging modalities when 2 different modes of stress (exercise treadmill vs intravenous dipyridamole plus handgrip) were used with SPECT imaging. Thus, Rb-82 PET provides improved specificity compared with TI-201 SPECT for identifying coronary artery disease, most likely due to the higher photon energy of Rb-82 and attenuation correction provided by PET. However, post-test referral cannot be entirely excluded as a potential explanation for the lower specificity of TI-201 SPECT.
引用
收藏
页码:1303 / 1310
页数:8
相关论文
共 30 条
[1]   TL-201 MYOCARDIAL PERFUSION IMAGING AT REST AND DURING EXERCISE - COMPARATIVE SENSITIVITY TO ELECTROCARDIOGRAPHY IN CORONARY-ARTERY DISEASE [J].
BAILEY, IK ;
GRIFFITH, LSC ;
ROULEAU, J ;
STRAUSS, HW ;
PITT, B .
CIRCULATION, 1977, 55 (01) :79-87
[2]   INTRAVENOUS DIPYRIDAMOLE COMBINED WITH ISOMETRIC HANDGRIP FOR NEAR MAXIMAL ACUTE INCREASE IN CORONARY FLOW IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
BROWN, BG ;
JOSEPHSON, MA ;
PETERSEN, RB ;
PIERCE, CD ;
WONG, M ;
HECHT, HS ;
BOLSON, E ;
DODGE, HT .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (06) :1077-1085
[3]   ASSESSMENT OF CORONARY-ARTERY DISEASE SEVERITY BY POSITRON EMISSION TOMOGRAPHY - COMPARISON WITH QUANTITATIVE ARTERIOGRAPHY IN 193 PATIENTS [J].
DEMER, LL ;
GOULD, KL ;
GOLDSTEIN, RA ;
KIRKEEIDE, RL ;
MULLANI, NA ;
SMALLING, RW ;
NISHIKAWA, A ;
MERHIGE, ME .
CIRCULATION, 1989, 79 (04) :825-835
[4]   QUANTITATIVE ROTATIONAL TL-201 TOMOGRAPHY FOR IDENTIFYING AND LOCALIZING CORONARY-ARTERY DISEASE [J].
DEPASQUALE, EE ;
NODY, AC ;
DEPUEY, EG ;
GARCIA, EV ;
PILCHER, G ;
BREDLAU, C ;
ROUBIN, G ;
GOBER, A ;
GRUENTZIG, A ;
DAMATO, P ;
BERGER, HJ .
CIRCULATION, 1988, 77 (02) :316-327
[5]  
DEPUEY EG, 1989, J NUCL MED, V30, P441
[6]   AN IMPROBABLE CRITERION OF NORMALITY [J].
DIAMOND, G .
CIRCULATION, 1982, 66 (03) :681-681
[7]   HOW ACCURATE IS SPECT THALLIUM SCINTIGRAPHY [J].
DIAMOND, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :1017-1021
[8]   MONKEY-BUSINESS [J].
DIAMOND, GA .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) :471-475
[9]  
ESQUERRE JP, 1989, J NUCL MED, V30, P398
[10]  
FRIEDMAN J, 1989, J NUCL MED, V30, P1718