ACUTE MYOCARDIAL-INFARCTION - COMPARISON OF T2-WEIGHTED AND T1-WEIGHTED GADOLINIUM-DTPA ENHANCED MR IMAGING

被引:37
作者
MATHEIJSSEN, NAA
DEROOS, A
VANDERWALL, EE
DOORNBOS, J
VANDIJKMAN, PRM
BRUSCHKE, AVG
VANVOORTHUISEN, AE
机构
[1] UNIV HOSP LEIDEN,DEPT DIAGNOST RADIOL,BLDG 1,C2-5,POB 9600,2300 RC LEIDEN,NETHERLANDS
[2] UNIV HOSP LEIDEN,DEPT CARDIOL,2300 RC LEIDEN,NETHERLANDS
关键词
D O I
10.1002/mrm.1910170217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance images were obtained from 32 patients with acute myocardial infarction, using a four‐echo technique (echo time (TE) = 30, 60, 90, and 120 ms) pre‐gadolinium(Gd)‐DTPA injection and a TE = 30 ms sequence pre‐ and post‐Gd‐DTPA. Intensity ratios of infarcted and normal myocardium were calculated, as were contrast‐to‐noise and signal‐to‐noise ratios. The four intensity ratios pre‐Gd‐DTPA were 1.20 ±0.15, 1.42 ± 0.22, 1.78 ± 0.38, and 1.99 ± 0.60 for TE = 30, 60, 90, and 120 ms, respectively, and 1.42 ± 0.19 post‐Gd‐DTPA (p = NS for post‐Gd‐DTPA vs TE = 60, p = 0.007 for TE = 90 vs TE = 120, p < 0.0001 for all other comparisons). The four contrast‐to‐noise ratios pre‐Gd‐DTPA were 1.69 ± 0.97, 2.69 ± 1.13, 3.17 ± 1.15, and 2.90 ± 1.09 for TE = 30, 60, 90, and 120 ms, respectively, and 2.71 ± 1.26 post‐Gd‐DTPA (p = NS for post‐Gd‐DTPA vs TE = 60, 90, and 120, p = NS for TE = 120 vs TE = 60 and 90, p< 0.01 for all other comparisons). The four signal‐to‐noise ratios pre‐Gd‐DTPA were 8.67 ± 1.47, 6.52 ± 0.76, 5.20 ± 0.64, 4.17 ± 0.53 for TE = 30, 60, 90, and 120 ms, respectively, and 9.17 ± 1.92 post‐Gd‐DTPA (p = 0.03 for post‐Gd‐DTPA vs TE = 30, p < 0.0001 for all other comparisons). In conclusion, the detectabilities of acute myocardial infarction were similar at TE = 60 ms and at Gd‐DTPA enhanced short‐TE MR imaging. However, image quality proved to be superior using the Gd‐DTPA enhanced short‐TE technique. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:460 / 469
页数:10
相关论文
共 15 条
[1]   VISUALIZATION OF MYOCARDIAL-INFARCTION AND SUBSEQUENT CORONARY REPERFUSION WITH MRI USING A DOG-MODEL [J].
AISEN, AM ;
BUDA, AJ ;
ZOTZ, RJ ;
BUCKWALTER, KA .
MAGNETIC RESONANCE IMAGING, 1987, 5 (05) :399-404
[2]   REVERSIBLE ISCHEMIC LEFT-VENTRICULAR DYSFUNCTION - EVIDENCE FOR THE HIBERNATING MYOCARDIUM [J].
BRAUNWALD, E ;
RUTHERFORD, JD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (06) :1467-1470
[3]   MYOCARDIAL PARAMAGNETIC CONTRAST AGENTS FOR MR IMAGING [J].
BROWN, JJ ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) :865-872
[4]   MR IMAGING OF ACUTE MYOCARDIAL-INFARCTION - VALUE OF GD-DTPA [J].
DEROOS, A ;
DOORNBOS, J ;
VANDERWALL, EE ;
VANVOORTHUISEN, AE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :531-534
[5]  
DROOS A, 1989, RADIOLOGY, V172, P717
[6]  
FILIPCHUK NG, 1987, AM J CARDIOL, V59, P1203
[7]   ACUTE MYOCARDIAL-INFARCTION - MR EVALUATION IN 29 PATIENTS [J].
FISHER, MR ;
MCNAMARA, MT ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :247-251
[8]   QUANTIFICATION OF EXPERIMENTAL MYOCARDIAL-INFARCTION USING NUCLEAR MAGNETIC-RESONANCE IMAGING AND PARAMAGNETIC ION CONTRAST ENHANCEMENT IN EXCISED CANINE HEARTS [J].
GOLDMAN, MR ;
BRADY, TJ ;
PYKETT, IL ;
BURT, CT ;
BUONANNO, FS ;
KISTLER, JP ;
NEWHOUSE, JH ;
HINSHAW, WS ;
POHOST, GM .
CIRCULATION, 1982, 66 (05) :1012-1016
[9]   ASSESSMENT OF MYOCARDIAL ISCHEMIA WITH PROTON MAGNETIC-RESONANCE - EFFECTS OF A 3 HOUR CORONARY-OCCLUSION WITH AND WITHOUT REPERFUSION [J].
JOHNSTON, DL ;
BRADY, TJ ;
RATNER, AV ;
ROSEN, BR ;
NEWELL, JB ;
POHOST, GM ;
OKADA, RD .
CIRCULATION, 1985, 71 (03) :595-601
[10]   DETECTION AND CHARACTERIZATION OF ACUTE MYOCARDIAL-INFARCTION IN MAN WITH USE OF GATED MAGNETIC-RESONANCE [J].
MCNAMARA, MT ;
HIGGINS, CB ;
SCHECHTMANN, N ;
BOTVINICK, E ;
LIPTON, MJ ;
CHATTERJEE, K ;
AMPARO, EG .
CIRCULATION, 1985, 71 (04) :717-724