A THIN-FILM RADIATION MONITORING LABEL AND DOSIMETRY SYSTEM

被引:12
作者
REHIM, FA
ABDELFATTAH, AA
机构
[1] National Center for Radiation Research and Technology, AEA, P.O. Box 29, Madinat Nasr, Cairo
关键词
D O I
10.1016/0969-8043(93)90010-8
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A thin plastic film was fabricated by casting on a polyester base a thin layer of poly(vinyl alcohol) (PVA) in aqueous solution with a mixture of dissolved sodium salt of 2,6-dichlorophenolindophenol (DPIP-Na) (a blue dye) and Sandolan Yellow N-3GL dye (SYN-3GL). This flexible, coated plastic film dosimeter undergoes a color change from green to yellow, with a sensitivity depending on DPIP-Na concentration. By changing the concentration of DPIP-Na in the film, one can predict the dose region at which the film will change its color from green to yellow. The response range of this dosimeter depends, in fact, on the DPIP-Na concentration and, in the case of 0.2 phr (by weight), it can be used up to absorbed doses of about 25 kGy, with a minimum useful dose of about 2 kGy. The effects of variation in concentration of DPIP-Na and thickness of film on response have been studied. The effects of absorbed dose, dose rate, temperature and relative humidity during irradiation and post-irradiation storage and exposure to daylight on dosimeter performance are also discussed. The usefulness of this dyed-film detector depends on its application. Using different concentrations of DPIP-Na, it can be applied as a green-to-yellow visual go-no-go monitor in the absorbed dose region 8-32 kGy. For dosimetry by spectrophotometry at 641 nm, the films show a linear response from 1 to 12 kGy.
引用
收藏
页码:1047 / 1053
页数:7
相关论文
共 25 条
[1]  
CHADWICK KH, 1977, IONIZING RAD METROLO, P195
[2]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[3]   QUALITY ASSURANCE FOR RADIATION PROCESSING [J].
KANTZ, AD ;
HUMPHERYS, KC .
RADIATION PHYSICS AND CHEMISTRY, 1979, 14 (3-6) :575-584
[4]   TEMPERATURE AND HUMIDITY EFFECTS ON THE GAMMA-RAY RESPONSE AND STABILITY OF PLASTIC AND DYED PLASTIC DOSIMETERS [J].
LEVINE, H ;
MCLAUGHLIN, WL ;
MILLER, A .
RADIATION PHYSICS AND CHEMISTRY, 1979, 14 (3-6) :551-574
[5]  
McLaughlin W., 1989, DOSIMETRY RAD PROCES
[6]  
Mclaughlin W.L., 1973, IAEA STIPUB311 PUBL, P577
[7]   PLASTIC FILM MATERIALS FOR DOSIMETRY OF VERY LARGE ABSORBED DOSES [J].
MCLAUGHLIN, WL ;
MILLER, A ;
ABDELRAHIM, F ;
PREISINGER, T .
RADIATION PHYSICS AND CHEMISTRY, 1985, 25 (4-6) :729-748
[8]  
MCLAUGHLIN WL, 1988, RADIAT PHYS CHEM, V31, P505
[9]  
MCLAUGHLIN WL, 1988, RADIAT PHYS CHEM, V31, P481
[10]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176