INTRINSIC PEEP MONITORED IN THE VENTILATED ARDS PATIENT WITH A MATHEMATICAL METHOD

被引:29
作者
EBERHARD, L
GUTTMANN, J
WOLFF, G
BERTSCHMANN, W
MINZER, A
KOHL, HJ
ZERAVIK, J
ADOLPH, M
ECKART, J
机构
[1] DRAGERWERK AKTIENGESELL,ENGN MED TECHNOL,W-2400 LUBECK,GERMANY
[2] DEPT ANESTHESIA & SURG INTENS CARE MED,W-8900 AUGSBURG,GERMANY
[3] DEPT SURG,CARDIAC & THORAC SURG CLIN,PHYSIOL CLIN,CH-4031 BASEL,SWITZERLAND
关键词
PHYSICAL MODEL OF RESPIRATORY SYSTEM; LEAST-SQUARES-FIT ALGORITHM; VENTILATORY PATTERN; EXPIRATORY TIME LIMITATION; INCOMPLETE EXPIRATION; INTRINSIC ALVEOLAR POSITIVE END-EXPIRATORY PRESSURE; END-EXPIRATORY PRESSURE DISTRIBUTION; VENTILATORY UNEVENNESS;
D O I
10.1152/jappl.1992.73.2.479
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Under mechanical volume-controlled ventilation, the intensive care patient can develop intrinsic positive end-expiratory pressure (iPEEP); that is, the passive expiration is terminated by the following inspiration before the alveolar pressure comes to its physical equilibrium value. We present a mathematical method to estimate this alveolar dynamic iPEEP breath by breath, without the need of a maneuver. We tested it in paralyzed patients ventilated for adult respiratory distress syndrome after multiple trauma and/or sepsis, and we compared the results obtained with the new mathematical method with those from the occlusion method introduced by Pepe and Marini. The results agreed well (median difference of 0.8 mbar in 201 investigations in 12 patients). However, the mathematically determined values, representing dynamic iPEEP, are systematically slightly smaller than those measured by the occlusion maneuver. A variation of expiratory time suggests that this, difference might be due to mechanical time-constant inhomogeneity, viscoelastic processes, or other mechanisms showing time dependence.
引用
收藏
页码:479 / 485
页数:7
相关论文
共 24 条
[1]  
BERTSCHMANN W, 1989, INTENSIVMED, V27, P42
[2]   MECHANICAL COMPLIANCE AND RESISTANCE OF THE LUNG-THORAX CALCULATED FROM THE FLOW RECORDED DURING PASSIVE EXPIRATION [J].
BRODY, AW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1954, 178 (02) :189-196
[3]  
BROSEGHINI C, 1988, EUR RESPIR J, V1, P726
[4]  
Brunner JX, 1988, PULMONARY FUNCTION I
[5]   MECHANICAL AND GAS-DISTRIBUTION BEHAVIOR OF A COLLATERAL VENTILATION MODEL [J].
CUTILLO, AG ;
DURNEY, CH ;
RENZETTI, AD .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (02) :503-511
[6]   ANALYSIS OF BEHAVIOR OF THE RESPIRATORY SYSTEM IN ARDS PATIENTS - EFFECTS OF FLOW, VOLUME, AND TIME [J].
EISSA, NT ;
RANIERI, VM ;
CORBEIL, C ;
CHASSE, M ;
ROBATTO, FM ;
BRAIDY, J ;
MILICEMILI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (06) :2719-2729
[7]  
GOTTFRIED SB, 1985, AM REV RESPIR DIS, V131, P414
[8]   DETERMINATION OF AUTO-PEEP DURING SPONTANEOUS AND CONTROLLED VENTILATION BY MONITORING CHANGES IN END-EXPIRATORY THORACIC GAS VOLUME [J].
HOFFMAN, RA ;
ERSHOWSKY, P ;
KRIEGER, BP .
CHEST, 1989, 96 (03) :613-616
[9]  
JONSON B, 1975, B PHYSIO-PATHOL RESP, V11, P729
[10]   NONINVASIVE MEASUREMENT OF RESPIRATORY MECHANICS IN ICU PATIENTS [J].
MILICEMILI, J ;
GOTTFRIED, SB ;
ROSSI, A .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1987, 4 (01) :11-20