SIZING THE GIANTURCO-ROUBIN CORONARY FLEXIBLE COIL STENT

被引:9
作者
HO, DSW [1 ]
LIU, MW [1 ]
YER, S [1 ]
PARKS, JM [1 ]
ROUBIN, GS [1 ]
机构
[1] UNIV ALABAMA,DEPT MED,DIV CARDIOVASC DIS,BIRMINGHAM,AL 35294
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1994年 / 32卷 / 03期
关键词
INTRACORONARY STENTS; SIZE; ANGIOPLASTY;
D O I
10.1002/ccd.1810320309
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The balloon expandable, stainless steel, flexible coil stent is a useful device for the management of acute or threatened closure after percutaneous transluminal coronary angioplasty. Appropriate sizing is important to optimize immediate results and reduce the risk of acute thrombosis and restenosis. The in vivo size at deployment of this stent at nominal inflation pressures has not been evaluated. Forty patients who received a single flexible coil stent (10 patients each for stent sizes 4.0, 3.5, 3.0, and 2.5 mm) were studied. The stents were deployed at 3-5 atmospheres. The actual stent size achieved by the stent during deployment was found to be significantly less than the nominal size, being 3.7 +/-0.3, 3.2 +/- 0.2, and 2.8 +/- 0.2 mm for nominal stent sizes of 4.0, 3.5, and 3.0 mm, respectively (P < 0.005, P < 0.001, and P < 0.01). For a 2.5 mm stent, it was 2.4 +/- 0.2 mm (P = ns). Thus, for optimal results with this device, we recommend that vessels 2.0-2.4 mm in diameter be supported by a 2.5 mm stent, vessels 2.5-2.9 mm in diameter by a 3.0 mm stent, vessels 3.0-3.4 mm in diameter by a 3.5 mm stent, and vessels 3.5-4.0 mm in diameter by a 4.0 mm stent. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 8 条
  • [1] AGRAWAL SP, IN PRESS
  • [2] CANNON A, 1993, INTERVENTIONAL CARDI
  • [3] EMERGENCY STENTING FOR REFRACTORY ACUTE CORONARY-ARTERY OCCLUSION DURING CORONARY ANGIOPLASTY
    DEFEYTER, PJ
    DESCHEERDER, I
    VANDENBRAND, M
    LAARMAN, GJ
    SURYAPRANATA, H
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15) : 1147 - 1150
  • [4] EMERGENT USE OF BALLOON-EXPANDABLE CORONARY-ARTERY STENTING FOR FAILED PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    HERRMANN, HC
    BUCHBINDER, M
    CLEMEN, MW
    FISCHMAN, D
    GOLDBERG, S
    LEON, MB
    SCHATZ, RA
    TIERSTEIN, P
    WALKER, CM
    HIRSHFELD, JW
    [J]. CIRCULATION, 1992, 86 (03) : 812 - 819
  • [5] MAIELLO L, 1993, AM HEART J, V125, P5700
  • [6] RODRIBUEZ A, 1993, AM J CARDIOL, V17, P1391
  • [7] INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    ROUBIN, GS
    CANNON, AD
    AGRAWAL, SK
    MACANDER, PJ
    DEAN, LS
    BAXLEY, WA
    BRELAND, J
    [J]. CIRCULATION, 1992, 85 (03) : 916 - 927
  • [8] EMERGENCY STENTING FOR ACUTE OCCLUSION AFTER CORONARY BALLOON ANGIOPLASTY
    SIGWART, U
    URBAN, P
    GOLF, S
    KAUFMANN, U
    IMBERT, C
    FISCHER, A
    KAPPENBERGER, L
    [J]. CIRCULATION, 1988, 78 (05) : 1121 - 1127