CONTINUOUSLY UPDATED 12-LEAD ST-SEGMENT RECOVERY ANALYSIS FOR MYOCARDIAL INFARCT ARTERY PATENCY ASSESSMENT AND ITS CORRELATION WITH MULTIPLE SIMULTANEOUS EARLY ANGIOGRAPHIC OBSERVATIONS

被引:141
作者
KRUCOFF, MW
CROLL, MA
POPE, JE
PIEPER, KS
KANANI, PM
GRANGER, CB
VELDKAMP, RF
WAGNER, BL
SAWCHAK, ST
CALIFF, RM
机构
[1] Cardiology Division, Duke University Medical Center, Durham, NC
关键词
D O I
10.1016/0002-9149(93)90729-V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Early angiography may not adequately subgroup patients with myocardial infarction if cyclic changes in coronary flow occur frequently. From a pilot experience using a new 12-lead ST-segment monitor, a continuously updated, self-referenced ST-recovery analysis method was developed to quantify both instantaneous recovery, as a noninvasive marker of patency, and cumulative ST recovery over time, as a marker of the speed, stability and duration of reperfusion. In 22 patients with acute infarction in whom 44 observations of unique angiographic patency were noted within 6 hours of presentation, serial patency assessments simultaneous with all angiographic observations predicted coronary occlusion with 90% sensitivity and 92% specificity. Of the 22 patients, 11 (50%) had multiple ST trend transitions suggesting cyclic changes in coronary flow before catheterization. Speed, stability and duration of ST-segment recovery were defined by the time to first 50% ST recovery, total number of ST-trend transitions and patent physiology index (percentage of monitoring period showing ST recovery), respectively. Sub-grouped angiographically, the median (interquartile range) for cumulative ST parameters with patent (n = 8) versus occluded (n = 14) arteries were, respectively - time to 50% recovery, 1.57 (1.16, 1.70) versus 0.17 (-0.47, 0.32) hours; number of reelevation/recovery events, 1.5 (1, 3) versus 3 (1, 3); and patent physiology index, 52 (47, 59) versus 50 (5, 73). Thus, continuous ST-segment recovery analysis appears to predict simultaneous angiographic patency over serial assessments, whereas cumulative parameters appear to contain independent information, probably because of patency changes before or after angiography.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 17 条
  • [1] BARBASH GI, 1990, BRIT HEART J, V64, P241
  • [2] EVALUATION OF COMBINATION THROMBOLYTIC THERAPY AND TIMING OF CARDIAC-CATHETERIZATION IN ACUTE MYOCARDIAL-INFARCTION - RESULTS OF THROMBOLYSIS AND ANGIOPLASTY IN MYOCARDIAL-INFARCTION PHASE-5 RANDOMIZED TRIAL
    CALIFF, RM
    TOPOL, EJ
    STACK, RS
    ELLIS, SG
    GEORGE, BS
    KEREIAKES, DJ
    SAMAHA, JK
    WORLEY, SJ
    ANDERSON, JL
    HARRELSONWOODLIEF, L
    WALL, TC
    PHILLIPS, HR
    ABBOTTSMITH, CW
    CANDELA, RJ
    FLANAGAN, WH
    SASAHARA, AA
    MANTELL, SJ
    LEE, KL
    [J]. CIRCULATION, 1991, 83 (05) : 1543 - 1556
  • [3] PREVENTION OF MYOCARDIAL-INFARCTION BY VERY EARLY TREATMENT WITH INTRACORONARY STREPTOKINASE - SOME CLINICAL OBSERVATIONS
    DAVIES, GJ
    CHIERCHIA, S
    MASERI, A
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (23) : 1488 - 1492
  • [4] DYNAMIC QRS-COMPLEX AND ST-SEGMENT MONITORING IN ACUTE MYOCARDIAL-INFARCTION DURING RECOMBINANT TISSUE-TYPE PLASMINOGEN-ACTIVATOR THERAPY
    DELLBORG, M
    RIHA, M
    SWEDBERG, K
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (05) : 343 - 349
  • [5] DYNAMIC QRS COMPLEX AND ST SEGMENT VECTORCARDIOGRAPHIC MONITORING CAN IDENTIFY VESSEL PATENCY IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION TREATED WITH REPERFUSION THERAPY
    DELLBORG, M
    TOPOL, EJ
    SWEDBERG, K
    [J]. AMERICAN HEART JOURNAL, 1991, 122 (04) : 943 - 948
  • [6] A COMPREHENSIVE ESTIMATION OF ACUTE MYOCARDIAL INFARCT SIZE USING ENZYMATIC, ELECTROCARDIOGRAPHIC AND MECHANICAL METHODS
    GRANDE, P
    HINDMAN, NB
    SAUNAMAKI, K
    PRATHER, JD
    HINOHARA, T
    WAGNER, GS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (15) : 1239 - 1244
  • [7] INTERMITTENT CORONARY-OCCLUSION IN ACUTE MYOCARDIAL-INFARCTION - VALUE OF COMBINED THROMBOLYTIC AND VASODILATOR THERAPY
    HACKETT, D
    DAVIES, G
    CHIERCHIA, S
    MASERI, A
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (17) : 1055 - 1059
  • [8] HACKWORTHY RA, 1986, BRIT HEART J, V56, P222
  • [9] THE PORTABLE PROGRAMMABLE MICROPROCESSOR-DRIVEN REAL-TIME 12-LEAD ELECTROCARDIOGRAPHIC MONITOR - A PRELIMINARY-REPORT OF A NEW DEVICE FOR THE NONINVASIVE DETECTION OF SUCCESSFUL REPERFUSION OR SILENT CORONARY REOCCLUSION
    KRUCOFF, MW
    WAGNER, NB
    POPE, JE
    MORTARA, DM
    JACKSON, YR
    BOTTNER, RK
    WAGNER, GS
    KENT, KM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (03) : 143 - 148
  • [10] NONINVASIVE DETECTION OF CORONARY-ARTERY PATENCY USING CONTINUOUS ST-SEGMENT MONITORING
    KRUCOFF, MW
    GREEN, CE
    SATLER, LF
    MILLER, FC
    PALLAS, RS
    KENT, KM
    DELNEGRO, AA
    PEARLE, DL
    FLETCHER, RD
    RACKLEY, CE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (11) : 916 - 922