RELIABILITY AND INTEROBSERVER VARIABILITY OF ULTRASONOGRAPHIC MEASUREMENT OF GASTRIC-EMPTYING RATE

被引:80
作者
IRVINE, EJ
TOUGAS, G
LAPPALAINEN, R
BATHURST, NC
机构
[1] MCMASTER UNIV,MED CTR,DEPT RADIOL,HAMILTON L8N 3Z5,ONTARIO,CANADA
[2] MCMASTER UNIV,MED CTR,DEPT MED,DIV GASTROENTEROL,HAMILTON L8N 3Z5,ONTARIO,CANADA
关键词
GASTRIC EMPTYING; REAL-TIME ULTRASOUND; RELIABILITY; OBSERVER VARIABILITY;
D O I
10.1007/BF01295904
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Scintigraphy and real-time ultrasound are valid techniques to measure parameters of gastric emptying. However, scintigraphy involves exposure to ionizing radiation, while the precision of real-time ultrasound has not been previously evaluated. The objectives of the present study were to determine the inter observer and day-to-day variability of liquid gastric emptying rate measured by real-time ultrasonography in healthy volunteers and to compare the gastric emptying rate of males and females. Twenty healthy volunteers had ultrasonographic measurement of gastric emptying rate after ingestion of 300 ml beef broth. Nine subjects had a concurrent assessment by a second observer. Nine subjects had two studies performed on different days by the same sonographer. The T1/2 for 20 subjects was 24.77 +/- 6.84 min with no difference between the half-emptying time for males (25.89 +/- 6.99 min) and females (24.02 +/- 6.94 min). The Pearson and intraclass correlation coefficients for observations made by two observers were 0.83 and 0.625, with a difference due to observer of 2.37 min +/- 5.26 (NS). The test-retest reliability across successive days was 0.136, representing considerable day-to-day variability within subjects. The variability between subjects was also large, explaining up to 79% of the total variance. We conclude that ultrasound is a useful method to evaluate gastric emptying with good interobserver agreement. Due to substantial day-to-day variability, sample sizes larger than previously suggested are required to demonstrate clinically important changes in gastric emptying rate in clinical trials.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 24 条
[1]  
BATEMAN DN, 1982, GUT, V23, P524, DOI 10.1136/gut.23.6.524
[2]   MEASUREMENT OF GASTRIC-EMPTYING TIME BY REAL-TIME ULTRASONOGRAPHY [J].
BOLONDI, L ;
BORTOLOTTI, M ;
SANTI, V ;
CALLETTI, T ;
GAIANI, S ;
LABO, G .
GASTROENTEROLOGY, 1985, 89 (04) :752-759
[3]   VARIABILITY OF GASTRIC-EMPTYING MEASUREMENTS IN MAN EMPLOYING STANDARDIZED RADIOLABELED MEALS [J].
BROPHY, CM ;
MOORE, JG ;
CHRISTIAN, PE ;
EGGER, MJ ;
TAYLOR, AT .
DIGESTIVE DISEASES AND SCIENCES, 1986, 31 (08) :799-806
[4]   TC-99M-HUMAN ALBUMIN MICROSPHERES (HAM) FOR MEASURING RATE OF GASTRIC EMPTYING [J].
CALDERON, M ;
SONNEMAKER, RE ;
HERSH, T ;
BURDINE, JA .
RADIOLOGY, 1971, 101 (02) :371-+
[5]   RELATIONSHIP BETWEEN IMPAIRED GASTRIC-EMPTYING AND ABNORMAL GASTROINTESTINAL MOTILITY [J].
CAMILLERI, M ;
BROWN, ML ;
MALAGELADA, JR .
GASTROENTEROLOGY, 1986, 91 (01) :94-99
[6]  
CHAUDURI TK, 1973, J NUCL MED, V15, P391
[7]   ROLE OF THE PROXIMAL AND DISTAL STOMACH IN MIXED SOLID AND LIQUID MEAL EMPTYING [J].
COLLINS, PJ ;
HOUGHTON, LA ;
READ, NW ;
HOROWITZ, M ;
CHATTERTON, BE ;
HEDDLE, R ;
DENT, J .
GUT, 1991, 32 (06) :615-619
[8]   GASTRIC-EMPTYING IN NORMAL SUBJECTS - A REPRODUCIBLE TECHNIQUE USING A SINGLE SCINTILLATION CAMERA AND COMPUTER-SYSTEM [J].
COLLINS, PJ ;
HOROWITZ, M ;
COOK, DJ ;
HARDING, PE ;
SHEARMAN, DJC .
GUT, 1983, 24 (12) :1117-1125
[9]  
DATZ FL, 1987, J NUCL MED, V28, P1204
[10]  
ELASHOFF JD, 1982, GASTROENTEROLOGY, V83, P1306